background image

5

9 Installation location

Important:

The gas alarm must not be installed:

Where conditions exceed the operating range. See section “Technical data” for further informa-

tion.

Directly above cooking appliances (min. 1 meter clearance).

Adjacent to an extractor fan.

Directly above sources of water, steam, or heat.

Outdoors, near a door, or window.

In enclosed places such as behind a curtain or in cupboards.

Where excessive dirt or debris may block the gas detection holes.

Natural gas is less dense than air and will rise above the level of escape (e.g., doors, windows) and get

trapped below the ceiling.
The product must be installed above potential gas escapes:

Horizontal ceilings: approx.30 cm from ceiling.

Sloped ceilings: approx. 50 cm from the roof ridge.

10 Installation

Important:

If necessary, drill holes and insert wall plugs. 

WARNING! Risk of electric shock or injury! Be-

fore drilling, check for concealed wires or pipes beneath the surface.

Risk of electric shock! Always disconnect the product from the power supply when installing or re-

moving.

The product must be connected to a stable power supply.

P

RECONDITIONS

:

a

There is a power outlet within range of the power cord.

a

The product is not connected to the power supply.

1. Use the holes on the mounting bracket as a template to mark where to drill.
2. Attach the bracket using the supplied dowels and screws.
3. Hang the product over the mounting bracket. Make sure the product is secure before letting go.

11 Connection

P

RECONDITIONS

:

a

Product is mounted in a suitable location.

a

The power supply has not been connected.

1. Connect the product to the power supply.
2. A confirmation tone will sound and the green power LED [Green: Power] will flash for approx. 3

minutes (start-up time).

à

When the green power LED 

[Green: Power]

 is constant on, the product is ready for use.

12 Operation

Important:

Avoid spraying air fresheners, hair spray, or other aerosols near the product! This may trigger the

alarm.

Clean the product regularly to prevent dust build-up. Pay close attention to the gas detection

holes. See section “Cleaning and maintenance”.

When the end of service light indicator [

Yellow: Service life

] lights up, disconnect the power sup-

ply, remove the product from use, and replace it with a new one.

The green power LED [

Green: Power

] must always be ON. This indicates that the power is ON

and everything is functioning correctly.

12.1 Alarm test

It is recommended to test the alarm at least once a month.
Short press the function button, the product will enter a short testing state.

A sound and light alarm will signal if the product is working correctly.

Remove the product from use and contact customer service if the alarms fail to activate.

12.2 Alarm activated

When the methane (CH

4

) gas levels reach the set alarming point, the detector will enter alarming mode.

When this happens:

The red alarm indicator [

Red: Alarm

] will flash.

The speaker will sound an alarm.

12.3 Action needed

Important:

The following actions are only suggestions and not in order of operation. The situation at hand may re-

quire different protocols. If in any doubt, consult a qualified professional to develop a suitable action

plan.

If the alarm has been triggered or the smell of gas is present, remain calm and perform the following ac-

tions:

Call the fire department from outside the premises.

Extinguish open or smouldering flames e.g. candles, cigarettes.

Turn off all gas appliances e.g. gas heater, gas cooker.

Do not switch ON/OFF any electrical equipment, including the gas detector.

Turn off the gas supply at the gas main control.

Open doors and windows to increase ventilation.

Warn all persons and evacuate the premises immediately.

Do not use a telephone when explosive gas is present.

Do not re-enter the premises until no more gas is present.

13 Application "Smart Life - Smart Living"

Important:

– The product is compatible with 2.4 GHz networks.
– Enter the exact network name (case sensitive).
– Connect the mobile device to the same Wi-Fi network the product will connect to.
– If you are giving the product to a third party you did not “Share Device” with, you may need to “Re-

move Device” through the application before they can link it to their account.

13.1 Features

Low battery warning.

Push notification for gas detected.

Check battery level and status record.

13.2 Download application

Compatible Android

TM

 and iOS apps are available from their respective app stores.

Search for “Smart Life - Smart Living”.

13.3 Bluetooth auto-scan

The product can be linked to the application automatically via Bluetooth®.
The option to connect may appear automatically or accessed through the following connection pathway:

All Devices → Add Device → Auto Scan.
P

RECONDITIONS

:

a

Bluetooth® is enabled on your mobile device and the application has permission to access it.

a

The product is in pairing mode.

1. Open the application and log in.
2. Navigate to: All Devices → Add Device.
3. Select “Add Device” and follow the on-screen instructions.

13.4 Product to application pairing

Connection pathway: Sensor → gas detector (Wi-Fi)

Available pairing methods are as follows:

Connection method

Available

QR code

No

AP mode

Yes

EZ mode

Yes

13.5 Open product for pairing

To open the device for pairing:
1. Restart the product by disconnecting then reconnecting the power supply.
2. During the start-up phase when the [

Green: Power]

 indicator is flashing, press and hold the Function

button until the [

Yellow: Service life]

 indicator flashes yellow.

à

When successfully paired to Wi-Fi, the 

[Yellow: Service life]

 indicator will go OFF.

à

Check the connection status using the app.

14 End of service life

Important:

When the end of service light indicator [

Yellow: Service life

] lights up, disconnect the power supply,

remove the product from use, and replace it with a new one.

The service life of this product is approximately 5 years under normal conditions. Make a note of the

installation date.

Regular cleaning and maintenance will help prolong use. See section “Cleaning and maintenance” for

further details.

Summary of Contents for 2498158

Page 1: ...Fachwerkstatt durchf hren 6 2 Handhabung Gehen Sie stets vorsichtig mit dem Produkt um St e Schl ge oder das Herunterfallen aus geringer H he k nnen das Produkt besch digen 6 3 Betriebsumgebung Setze...

Page 2: ...Sorgen Sie insbesondere daf r dass die ff nungen f r die Gasmessung frei bzw sauber bleiben Weitere Informationen dazu finden Sie im Abschnitt Reinigung und Wartung Leuchtet die LED Anzeige f r das E...

Page 3: ...Produkt von der Stromversorgung 2 Nehmen Sie dann das Produkt von dem Montageb gel herunter 3 Nehmen Sie nun einen Staubsauger mit B rstenaufsatz zur Hand stellen Sie eine niedrige Saugleis tung ein u...

Page 4: ...roduct 6 3 Operating environment Do not place the product under any mechanical stress Protect the appliance from extreme temperatures strong jolts steam and solvents Protect the product from high humi...

Page 5: ...will sound an alarm 12 3 Action needed Important The following actions are only suggestions and not in order of operation The situation at hand may re quire different protocols If in any doubt consult...

Page 6: ...unsorted municipal waste Spent batter ies and accumulators which are not enclosed by the WEEE as well as lamps that can be re moved from the WEEE in a non destructive manner must be removed by end use...

Page 7: ...faible hau teur peuvent endommager le produit 6 3 Conditions environnementales de fonctionnement N exposez pas le produit des contraintes m caniques Prot gez l appareil des temp ratures extr mes des...

Page 8: ...Power doit toujours tre allum Ce signal lumineux indique que l appareil est allum et que tout fonctionne correctement 12 1 Test d alarme Il est recommand de tester l alarme au moins une fois par mois...

Page 9: ...aisissez le num ro de commande du produit dans le champ de recherche pour pouvoir t l charger la d claration de conformit de l UE dans les langues disponibles 18 limination des d chets Tous les quipem...

Page 10: ...een val van geringe hoogte kunnen het pro duct beschadigen 6 3 Bedrijfsomgeving Stel het product niet aan mechanische spanning bloot Bescherm het apparaat tegen extreme temperaturen harde klappen sto...

Page 11: ...dat het product stroom ontvangt en alles goed werkt 12 1 Alarmtest Wij raden u aan het alarm minstens eens per maand te testen Druk kort op de functieknop om het product op een korte testmodus te sch...

Page 12: ...ds Voer het bestelnummer van het product in het zoekveld in vervolgens kunt u de EU conformiteitsverkla ring downloaden in de beschikbare talen 18 Verwijdering Alle elektrische en elektronische appara...

Reviews: