Page : 11
________________________________________________________________________________________________
HYDRO’pH
®
,
HYDR’ORP
®
,
HYDRO’pH Duo
®
and
HYDRO’pH/ORP
®
instructions
c)
HYDR’ORP
®
with power socket 2P+E
Execution:
HYDR’ORP
®
wall mounted electronic box
230v 50Hz power supply
ORP sensor resistant to pressure (6 bars) with the possibility of installing at 90°
compared with the vertical position..
Standard power socket 2P+E 230v 3A max.
Hydraulic connections for pool pipe in Ø 50mm or Ø 63mm
Options:
Level sensor for tank bottom
Connections kit
Packaging :
Redox (ORP)
Fixation kit
sensor
for ORP sensor
HYDR’ORP Controller
Fixation kit
Kit of mural
with power socket
for box
screws
Codifications: HYDR’ORP socket controllers
Code
Reference
HYDR’ORP
®
Socket
electronic box
Power
supply
Measuring
sensor
Dosing
device
Protection
class
HYD 1124
Standard equipment Ø50
with cable 1m 3x 0,75 mm
2
230V
50/60Hz
ORP with
6m of cable
Socket
2P+E
IP54
NOTE:
For equipment maintenance, spare parts are available in the «
accessories » section.
▲ See section « accessories »
d)
HYDRO’pH Duo
®
Execution:
HYDRO’pH Duo
®
wall mounted electronic box
230v 50Hz power supply
pH sensor resistant to pressure (6 bars) with the possibility of installing at 90° compared
to the vertical position.
Integrated metering pump of 0,4 or 0,8 or 1,6 or 2,4 liters/hour.
Hydraulic connections for pool pipe in Ø 50mm or Ø 63mm
Options:
Level sensor for tank bottom
Connections kit