SY SY-MMU Series Installation Manual Download Page 14

SY-MMU-88A / 1616 / 3232 / 6464 

 

www.sy.co.uk

 

14

 

Safety Instructions 

To ensure reliable operation of these product as well as protecting the safety of any person using or 
handling these devices while powered, please observe the following instructions. 

1.

 

Use the power supplies provided. If an alternate supply is required, check Voltage, polarity and 
that it has sufficient power to supply the device it is connected to. 

2.

 

Do not operate either of these products outside the specified temperature and humidity range 
given in the above specifications. 

3.

 

Ensure there is adequate ventilation to allow this product to operate efficiently. 

4.

 

Repair of the equipment should only be carried out by qualified professionals as these products 
contain sensitive devices that may be damaged by any mistreatment. 

5.

 

Only use these products in a dry environment. Do not allow any liquids or harmful chemicals to 
come into contact with these products. 

6.

 

Due to the weight and physical size of some of these matrix switchers, correct Manual Handling 
and Lifting procedures should be observed at all times while handling these products in order 
to minimise the risk of injury. 

After Sales Service 

1.

 

Should you experience any problems while using this product, firstly refer to the Troubleshooting 
section in this manual before contacting SY Technical Support. 

2.

 

When calling SY Technical Support, the following information should be provided: 

 

Product name and model number 

 

Product serial number 

 

Details of the fault and any conditions under which the fault occurs. 

3.

 

This product has a two year standard warranty, beginning from the date of purchase as stated on 
the sales invoice. Online registration of this product is required to activate the full three year 
extended warranty. For full details please refer to our Terms and Conditions. 

4.

 

SY Product warranty is automatically void under any of the following conditions: 

 

The product is already outside of its warranty period 

 

Damage to the product due to incorrect usage or storage 

 

Damage caused by unauthorised repairs 

 

Damage caused by mistreatment of the product 

5.

 

Please direct any questions or problems you may have to your local dealer before contacting SY 
Electronics. 

 

 

Summary of Contents for SY-MMU Series

Page 1: ...ed Kingdom Tel 44 0 161 868 3450 Fax 44 0 161 868 3459 www sy co uk Installation Guide 8 x 8 Matrix Switcher 16 x 16 Matrix Switcher 32 x 32 Matrix Switcher 64 x 64 Matrix Switcher 4K HDMI DVI HDBT SD...

Page 2: ...video sources and displays up to 4K resolution Up to 8 16 or 32 inputs from media players blue ray players sources Up to 8 16 or 32 outputs to displays projectors Multi Format input and output combina...

Page 3: ...Video Only selection sequence SY MMU 88A only Audio Starts a new Audio Only selection sequence SY MMU 88A only Comma Separates output selections SY MMU 1616 and higher Enter Completes a new command en...

Page 4: ...S232 control commands IEC connector 100 to 240 V AC power mains input Earthing Stud Earth ground bonding point Audio Inputs Independent audio inputs on SY MMU 88A only Note that the SY MMU 88A has onl...

Page 5: ...or DVI signals whereas the output card will output HDMI or DVI signals from any input card Figure 7 Seamless DVI Input and Output Cards The input card can either accept HDMI DVI VGA YPbPr or C Video s...

Page 6: ...n be identified by the 4K icon on the outer edge of the connector panel Figure 10 HDMI Input and Output Cards The input card can either accept HDMI or DVI signals as well as analogue audio whereas the...

Page 7: ...Alternatively connect an earth bonding strap to the earthing point on the rear of the SY Matrix unit and a good local earth point SY MMU 88A Audio Switcher The SY MMU 88A matrix switcher features an...

Page 8: ...Buttons For the SY MMU 1616 and SY MMU 3232 there is both a comma button and an Enter button The comma button is used to separate the output channel values when a single input is being sent to multipl...

Page 9: ...nse Check the matrix type Type Returns the SY Matrix model number Lock the front panel buttons Lock System spc Locked cr lf Unlock the front panel buttons Unlock System spc Unlocked cr lf Check the so...

Page 10: ...ut numbers More outputs may be specified if required each separated by a comma Note 4 xBy z Select Video input x to a single output y Note 3 x is the input number y is the output number xVy Select Vid...

Page 11: ...the VGA card input resolution to 1080 x 720 for input x USER I x 0627 0627 cr lf Set the VGA card input resolution to 1080 x 800 for input x USER I x 0628 0628 cr lf Set the VGA card input resolution...

Page 12: ...SY MMU 88A 1616 3232 6464 www sy co uk 12 Figure 12 SY MMU 1616 Connection Diagram...

Page 13: ...sical All the matrix switchers in the SY MMU range are full width 19in rack mounting with integral fixing holes and handles Product SY MMU 88A SY MMU 1616 SY MMU 3232 SY MMU 6464 Width 483 mm 19 483 m...

Page 14: ...s correct Manual Handling and Lifting procedures should be observed at all times while handling these products in order to minimise the risk of injury After Sales Service 1 Should you experience any p...

Page 15: ...SY MMU 88A 1616 3232 6464 15 www sy co uk NOTES...

Page 16: ...SY MMU 88A 1616 3232 6464 www sy co uk 16 NOTES...

Reviews: