Operation

 

Manual

Sy

Klone.com/RAinfo

June

 

2021

Identification and Function of Parts

The cab alarm sounds when cab pressure drops below the low-pressure threshold for three seconds or increases above the high-pressure threshold for six 
seconds, or when CO

2

levels exceed thresholds (alarms are user-adjustable). Alarm state resets when the cab conditions return to the acceptable range or when 

the power is cycled off/on. 

ENGLIT0000342

 

D

5

Main Display Screen

The touch screen display shows, in 
real time, the cab pressure, CO

2

level, user-adjustable alarm levels, 
and the current filter(s) installed. 

Section 2: Introduction

The RESPA  monitor provides the pressure difference between the outside, ambient pressure and the internal pressure of an 
enclosure, the CO

2

PPM (parts per million) level within the enclosure, and real-time indication of filter usage. This document gives 

instruction on installing and using the RESPA  in an enclosed cab.

General Information

The main module should be installed within the operator’s line of sight.

The cab must be sealed and able to maintain pressure; check that all seals and 
gaskets are intact and add extra sealant where necessary. 

This unit works with 12/24 VDC systems. The system should be connected so it 
is powered when the key is turned on.

The system utilizes a pressure-sensitive, LCD touch screen. Do not use anything 
sharp on the touch screen, as it may cause screen damage. 

When mounting the ambient pressure sensor (APS), mount sensor to exterior of 
cab, in a non-pressurized protected area, such as the exterior rear wall, where it 
will not be impacted by dirt, exposed to wind or direct airflow during machine 
movement, or exposed to excessive moisture. 

To assist in mounting the APS, an optional APS mounting/wiring kit that attaches 
to an existing RESPA

®

mount, which includes mounting adapter, bolts, and a 

wiring Y-harness to connect to the RESPA power source is available through 
your authorized Sy-Klone reseller. 

Customizable Settings

Display pressure readings in Pascal or Inches of H

2

0

Low-pressure alarm threshold with adjustable time to alarm

High-pressure alarm threshold with adjustable time to alarm

Primary CO

2

PPM alarm threshold

Secondary CO

2

PPM alarm interval

Adjustable alarm volume

Monitor Default Settings

Sound: 

On

Volume: 

75% of maximum volume level 

Primary Alarm Mute: 

Infinite 

Secondary Alarm Mute:

5 minutes

Pressure Units: 

Pascal

Low Alarm Threshold: 

20 Pascal at 3 seconds

High Alarm Threshold: 

200 Pascal at 6 seconds

CO

2

Alarm Thresholds: 

Primary 1000 PPM, Secondary 2500 PPM

Main menu 
button

200

1000

1

000

20

CO

2

FEFF218

PF ISO 35 H

H13 HEPA

50

Cab differential 
pressure level

High and low 
pressure alarm 
thresholds

Pressure unit of 
measure

Silence 
alarm button

CO

2

PPM level

Filter selection  
buttons

Filter identification 
display

High CO

2

PPM 

threshold

1

LCD touch 
screen display 

shows real-time 
cab pressure, 
CO

2

level, alarm 

levels, and filter 
type(s).

CO

2

sensor inlet 

vents on top and 
bottom of unit.

Electrical 

cable with 

Deutsch connector for 
DC voltage connection 
for 12/24 VDC 
systems.

MAIN MODULE - MONITOR 

(in cab)

AMBIENT PRESSURE SENSOR (APS) 

(exterior of cab)

Pressure port 

Mount APS where 
port is protected 
from debris build-up.

Summary of Contents for ADVISOR RESPA

Page 1: ...OPERATION MANUAL Sy Klone com RAinfo In cab Main Module External Ambient Pressure Sensor APS ISO 23875 Compliant ...

Page 2: ...Hardware Setup 6 Manual Filter Identification 7 Manual Filter Setup 7 Section 5 User Options Setting Options 8 Alarm Volume Setting 8 Pressure Units of Measure Setting 9 Pressure Alarm Setting 9 Filter Life Setting 9 Filter Identification Specifications 10 Mute Length Setting 11 CO2 Alarm Threshold Setting 11 Pin Code Setting 11 Section 6 User Operation Filter Identification 12 Filter Life Screen ...

Page 3: ... cab Storage Temperature Rating 55 C to 125 C Operating Pressure Range 0 to 400 Pascal Pa 0 to 1 61 Inches H2O Operating CO2 Range 0 to 5000 ppm Display Resolution 1 Pa 0 01 Inches H2O Weight Main Module 426 0 g 15 0 oz Ambient Pressure Sensor 368 5 g 13 1 oz Connector Deutsch part number DT04 2P E005 qty 1 W2P secondary lock qty 1 0460 202 16141 contact pins qty 2 Dimensions Main Module 164 8 x 7...

Page 4: ...ep to establishing better visibility to operator enclosure conditions on your job site Before installing the monitor we encourage you to read through the full operation manual including mounting and wiring instructions and download the RESPA Advisor smart phone app Additional information and support is available online or through your authorized Sy Klone reseller Access Online Support Resources Vi...

Page 5: ...cab in a non pressurized protected area such as the exterior rear wall where it will not be impacted by dirt exposed to wind or direct airflow during machine movement or exposed to excessive moisture To assist in mounting the APS an optional APS mounting wiring kit that attaches to an existing RESPA mount which includes mounting adapter bolts and a wiring Y harness to connect to the RESPA power so...

Page 6: ...be used for main module installation If needed Sy Klone offers a wiring harness kit RCF2915 that includes 20 feet of wire with Deutsch connector and heat shrink zip ties and clamps to secure cable Wiring both units The monitor power leads can be connected to any convenient DC voltage connection point meeting these criteria The supply voltage must be between 10 VDC and 28 VDC The voltage source is ...

Page 7: ...n button 2 4 or 6 8 to manually install the selected filter into the install filter display 3 The installed filter will then populate in the Installed Filter display and the filter location will turn black to indicate a filter has been installed 4 Press the Confirm button when all selections are correct and return to the main menu To exit without saving changes press the Main Menu button or Cancel...

Page 8: ...adjust the alarm volume or press the Reset button to return the volume to the default 75 of maximum volume level 2 Press the Confirm button to confirm any changes and return to the main menu screen To exit without saving changes press the Main Menu button or Cancel button to return to the Main Menu screen or press the Home button to return to the main display 200 1000 1 000 20 CO2 FEFF218 PF ISO 3...

Page 9: ...s below 1 Use the Up Down Filter Selection buttons to select the installed filter you would like to adjust 2 Use the Up Down Adjust Hours buttons to adjust the filter life hours The maximum allowable time is determined by filter type See Filter Identification Specifications next page 3 If you wish to restore default value press the Reset button to return the filter life hours to maximum allowed 4 ...

Page 10: ...Filter PF F9 MERV 16 STD FEFF208 750 FEFF209 Extended Length F9 MERV 16 Fresh Air Ported Filter PF F9 MERV 16 EXTD FEFF209 1000 FEFF210 Standard Length H13 HEPA Recirc Air Closed Filter PF H13 HEPA STD FEFF210 500 FEFF211 Standard Length F9 MERV 16 Recirc Air Closed Filter PF F9 MERV 16 STD FEFF211 750 FEFF212 Extended Length F9 MERV 16 Recirc Air Closed Filter PF F9 MERV 16 EXTD FEFF212 1000 FEFF...

Page 11: ...current PIN code 1 From the main display screen press the Main Menu button 2 Enter 999999999 nine 9 s in the settings PIN Code screen 3 Press the Confirm button to enter the Main Menu and create a new 5 digit PIN code in the PIN Code Menu To create a new PIN code NOTE Only 5 digit PIN codes can be created and saved 1 Enter the current PIN code to access the Main Menu 2 Press the PIN Code Menu butt...

Page 12: ...n Press Filter Identification display on the Home screen to enter Filter Life screen The maximum filter life hours are determined by the filter type See Filter Identification Specifications page 10 The filter life bar will diminish from right to left All installed filters can be viewed by using the Up Down Filter Selection buttons Press the Home button to return to the main display 200 1000 1 000 ...

Page 13: ... the monitor is reset cycled off on The audible alarm generated by the primary set CO2 PPM alarm threshold can be muted See Muting the Alarm page 14 If the CO2 PPM level reaches 2500 PPM the secondary non adjustable CO2 PPM alarm will sound and it is only able to be muted for a set interval between 0 10 minutes until cab conditions return to within thresholds Filter Life Warning and Alarm When the...

Page 14: ...larm button to silence the audible alarm The Silence Alarm button will remain until the alarm condition is resolved ENGLIT0000342 D 14 Silence Alarm Button Alarm Button Bluetooth Setting If the background of the Pressure Display on the main display is not showing Red Amber or Green the APS has not connected Reconnecting Instructions 1 To restart cycle power to the RESPA Advisor 2 If the APS does n...

Page 15: ...ogging Download Please visit www sy klone com RAinfo or scan the QR code provided in the information screen for instructions on how to access to the Sy Klone phone application 1 On the monitor press the Download Logs button to allow the Sy Klone phone application to connect to the RESPA Advisor 2 Follow the prompts within the Sy Klone phone application to download the logs to your mobile device 3 ...

Reviews: