Operation
Manual
Sy
‐
Klone.com/RAinfo
June
2021
ENGLIT0000342
D
15
10 SECS
Confirm button
(erase logs)
Cancel button
Main menu
button
Info button
Home
button
Reset
button
List of data sampling
intervals
Select
data sampling
interval
Download
logs
button
Data Logging Interval Setting
To access the
Data Logging screen
, press the
Data logging button
on the Main Menu.
1. Use the
Up/Down Data Sampling Interval
buttons
to adjust the interval at which samples
are logged.
NOTE:
Selecting one second
intervals will give you a log of approximately one
hour, ten second intervals will give you a log of
approximately 10 hours, etc.
2. Press the
Reset button
to return the data
sampling interval to 10 seconds.
3. Press the
Confirm button
to confirm any
changes and return to the Main Menu screen.
NOTE:
If you press the
Confirm button,
all
previous logging will be erased.
Data Logging Download
Please visit
www.sy-klone.com/RAinfo
or scan the QR code provided in the information screen for
instructions on how to access to the Sy-Klone phone application.
1. On the monitor, press the
Download Logs button
to allow the Sy-Klone phone application to
connect to the RESPA .
2. Follow the prompts within the Sy-Klone phone application to download the logs to your mobile
device.
3. Press the
Home button
to return to the main display.
4. Press the
Main Menu button
to return to the Main Menu screen.
NOTE:
Pressing the
Confirm button
will erase all previous logs.
Recalibrating the Monitor
If you are seeing erratic readings, or if you open the cab door and the pressure does not drop to zero, it is time to recalibrate the
monitor.
To recalibrate the RESPA :
1. Press the
Main Menu button
on the main display.
2. The
PIN Code Screen
will be displayed.
a. Enter the six-digit recalibration PIN code. (
777779
)
TIP:
If you enter number incorrectly, press the
Reset button
to clear entry.
b. Press the
Confirm button
to restart and recalibrate the monitor.