第
6
页
以下情况需要做归零校正:
Always correct the calibration after the following instances:
1.本装置安装完成后
After installation.
尺寸出现异常不稳定时
If the device is feeding irregularly.
感应轮在无负载的状态(移开感应轮上的松紧带),在任何一段工程中,送料值在 980~990 之间,
(灵敏度必须设定在 99),而驱动轮未停止转动时
If the driven roller can not stop. In any section.The driven roller must stop when the tension
value to be adjusted between 980-990 and the sensitivity is set at 99 after remove the elastic
tape from the sensor bar (Make sure nothing Contact with Sensor Bar).
归零校正
0KG CALIBRATION
操作指引:
Operation guide:
压力系数
050
Pressure
0KG SET
→
050
1KG SET
600
压力系数
050
Pressure
0KG SET
→
054
1KG SET
600
→
1. Beep Set
2. Zero Set
3. Current Set
4. Setector Set
→
1.
报警设定界面
2.
归零设定界面
3.
电流设定界面
4.
带料设定界面
(
长按
3
秒
)
(Keep press for 3 second
)
注意:如果归零后,其数值不介于
10~90
之间,则表示装置有问题,需要检修
Notice:if the value is not between 10 ~ 90 after regular calibration.the device need to be repaired.
归零校正时应移开感应轮之松紧带(如下图 )
Please remove the elastic tape before calibration (Refer to the following figure).