background image

Operating Instructions

10

Sensor

Material

Housing: Stainless steel 1.4571

Sensor-isolation: POM

Protective system

IP 65

Using in EX-Zones

As ProGap S Ex-sensor in DustEx-zone 20/22 
and GasEx-zone 0/2 only with process-adapter

Process temperature

-20 …  +  80 °C  
-20 … +220 °C  (with process-adapter) 

max. 1000 °C  (with ceramic flange)

Ambient temperature

-20 … +60 °C

Working pressure

max.   1 bar   

max.  20 bar  (with process-adapter)

Detection range

0 …   4 m

0 … 18 m

> 18 m (on demand)

Power supply

12 V DC powered by DIN Rail electronic

Power consumption

approx. 1.8 VA

Current consumption

max. 100 mA

Measuring frequency

K-Band 24.125 GHz (± 100 MHz)

Transmitting power

max. 5 mW

Weight

Transmitter:  approx. 560 g

Receiver:      approx. 560 g

SWR engineering Messtechnik GmbH

Gutedelstraße 31 · 79418 Schliengen (Germany)
Fon +49 7635 82 72 48-0 · Fax +49 7635 82 72 48-48 · www.swr-engineering.com

9.  Technical Data

DIN Rail electronic

Power supply

24 V DC ± 10 % 

Power consumption

3.5 W

Current consumption

120 mA at 24 V

Relay (max.)

•  Voltage 

•  Current

•  Capacity

 

250 V AC  

1 A 

60 W

Fall-delay time

0.25 … 5 s (continuously adjustable)

Weight

approx. 172 g

Protective system

IP 40

Mounting with separating flange

Mounting with pipe clamp

Thread mounting

A

B

Mounting types

The ProGap S can be easily installed in the following  
ways:

• 

Screwing it into a G 1½-inch threaded connection,

• 

using a DN 40 flange or 

• 

using a pipe clamp or other holding bracket.

(All rights reserved.)

EN 24/11/2015

certificated
according to

 

ATE X

Summary of Contents for ProGap S

Page 1: ...SWR engineering Messtechnik GmbH ProGap S Microwave barrier Betriebsanleitung EN Operating Instructions...

Page 2: ...2 CONTENTS Page 1 General 3 2 Mounting and Installation 3 3 Electrical Connection 4 3 1 Safety Instructions 5 4 Safety 7 5 Commissioning 8 6 Trouble Shooting 9 7 Notice 9 8 Declaration of Conformity...

Page 3: ...ures up to 20 bar as well as all DustEx zones the ProGap S can be used with the help of a process adapter 2 Mounting and Installation The device can be installed at any installation height However it...

Page 4: ...on the metallic wall on the opposite side of the bin can be used for the reflection of the microwave The arrangement of transmitter and receiver mustn t be exactly parallel to each other in this insta...

Page 5: ...oup Equipment category For explosive mixtures of air and combustible dusts Degree of protection Maximum surface temperature at maximum ambient temperature Ta 60 C 3 1 Safety Instructions Hazardous Are...

Page 6: ...safety instructions in the operating instructions 2 Install the device according to the manufacture s instructions and any other valid standards and regulations 3 The device may not be operated outsid...

Page 7: ...microwave barrier must be installed by trained and authorised personnel only In case of maintenance work on the pipe or on components of the ProGap S sensor make sure that the piping is in unpressuri...

Page 8: ...only rotate P1 counter clockwise until LED 1 is turned off Repeat the process If LED 1 continues to glow even if P1 is turned all the way to the left and if the materials are materials with a low die...

Page 9: ...ransmitter and receiver the maximum detection range is limited 7 Notice Avoid reflections on metal parts 8 Declaration of Conformity The described product meets the requirements of the following Europ...

Page 10: ...ng power max 5 mW Weight Transmitter approx 560 g Receiver approx 560 g SWR engineering Messtechnik GmbH Gutedelstra e 31 79418 Schliengen Germany Fon 49 7635 82 72 48 0 Fax 49 7635 82 72 48 48 www sw...

Reviews: