![SWP 9032H Operator'S Manual Download Page 8](http://html1.mh-extra.com/html/swp/9032h/9032h_operators-manual_1416139008.webp)
3 INSTALLATION
3.1 Unpacking
Use the packing lists to identify and account for each item.
3.1.1 Inspect each item for possible shipping damage. If damage is evident, contact
your distributor and / or shipping company before proceeding with the
installation.
3.1.2 When using a forklift, its arm length must be long enough to reach the outside
so as to ensure safe lifting.
3.1.3 The movement may cause potential danger or substantive hazard. Make sure
the machine is in a safe position before using.
3.2 Input Power Connections
Supply input connection of CUT 60 power is shown as the Fig 3.1.
3.2.1 Check your power source for correct voltage before plugging
in or connecting the unit
3.2.2 Power Cord and Plug. This power supply includes an
input power cord and plug suitable for 220V AC 1 –
Phase input power.
3.2.3 If the power supply voltage continually goes beyond
the range of safe work voltage range, it will shorten
the machine’s life-span. The following measures can
be used:
• Change the power supply input, eg. connect the
machine with the stable power supply voltage of
distributor.
• Reduce the machine’s power supply at the same
time.
• Set the voltage stabilisation device in the front of power cable input.
3.3 Gas Connections
3.3.1
Connecting Gas Supply to Unit
Connect the gas line to the inlet port of the gas filter on the rear panel.
3.3.2
Check Air Quality
To test the quality of air, put the RUN / SET switch in the SET (down) position.
Check if there is any oil or moisture in the air.
6
§3 Installation
3. 1 Unpacking
Use the packing lists to identify and account for each item.
1.
Inspect each item for possible shipping damage. If damage is evident, contact your distributor and / or
shipping company before proceeding with the installation.
2.
When using forklift, its arm length must be long enough to reach the outside so as to ensure lifting
safely.
3.
The movement may bring the potential danger or substantive hazard, so please make sure that the
machine is on the safe position before using.
3.2 Input Power Connections
Supply input connection of CUT 100 power is shown as the
Fig3.1.
1.
Check your power source for correct voltage before plugging in
or connecting the unit
2.
Power Cord and Plug This power supply includes an input power
cord and plug suitable for 380V AC 3 - Phase input power.
3.
If the power supply voltage continually goes beyond the range of
safe work voltage range, it will shorten the welder life-span. The
following measures can be used:
l
Change the power supply input. Such as, connect the welder with
the stable power supply voltage of distributor;
l
Reduce the machines using power supply in the same time;
l
Set the voltage stabilization device in the front of power cable
input.
3. 3Gas Connections
1.
Connecting Gas Supply to Unit
Connect the gas line to the inlet port of the gas filter on the rear panel.
2.
Check Air Quality
To test the quality of air, put the RUN / SET switch in the SET (down) position, check if there are Any
oil or moisture in the air.
Live wire
Earth wire
3
~
380V
Power
cable
Rear panel
Distrubutor
Earth wire
Live wire
Power
input
Power
switch
Power
cable input
Fig 3.1 the connect method of
the main supply
STEALTH DIGI-CUT 100 CNC
8
Fig. 3.1 Correct method
of main supply