background image

 

 

14 

Net 

This setting is only available when the Art-Net version is set to 

Art-Net 3 

or with firmware versions prior to version 

1.01. 

To adjust the Art-Net net of the node, navigate to 

Home > Menu > Art-Net > Net

 and adjust the number using the 

encoder wheel. Once the desired number has been selected, push [OK] to apply the new setting or press [Cancel] to 
abort. 

This part of the Art-Net address was introduced with Art-Net 3. In order to work with Art-Net I and Art-Net II 
controllers, Art-Net net needs to be set to 0. 

Note that changing this setting while independent Art-Net universes are enabled still affects all Art-Net port 
addresses. For more information, see Independent Universes below. 

Sub-Net 

This setting is only available when the Art-Net version is set to 

Art-Net 3 

or with firmware versions prior to version 

1.01. 

The Art-Net sub-net is configured under 

Home > Menu > Art-Net > Sub-Net

 in the same way the Net is configured. 

Note that changing this setting while independent Art-Net universes are enabled still affects all Art-Net port 
addresses. For more information, see Independent Universes below. 

Independent Universes 

This setting is only available with firmware versions that appeared before version 1.01. Newer firmware versions 
provide the same functionality when the Art-Net version is set to 

Art-Net 4

. The main advantage of the Art-Net 4 

support over the obsolete independent universes functionality is that Art-Net 4 support allows an Art-Net 4 aware 
controller to properly understand and, if supported by the controller, configure the port address of each port 
whether the ports share a common net and sub-net address or not. 

Independent Art-Net universes may be enabled and disabled under 

Home > Menu > Art-Net > Independent Universes

If independent Art-Net universes are enabled, the ports of the Art-Net node do not need to share the same Art-Net 
net and sub-net addresses. 

When this feature is enabled, each output port has an independent port address in the range of 0 to 32767, which is 
computed from the Art-Net net, sub-net and universe number. This allows for configuring the node to any combination 
of  Art-Net  universes.  However,  if  the  Art-Net  net  or  the  Art-Net  sub-net  settings  are  changed  (remotely  or  in  the 
menu), each output port address is recomputed. For more information on the addressing of the Art-Net ports, see 
section Representations of Art-Net Port Addresses in the appendix. 

Unfortunately, due to restrictions of Art-Net, the node may no longer correctly report the port addresses of its outputs 
to a controller when this feature is enabled, which might confuse a controller and lead to problems. Therefore, it is 
recommended to avoid enabling independent universes whenever possible. 

Name 

The device name can be viewed and edited under 

Home > Menu > Art-Net > Name

Deleting Text 

 

To delete a text line or a part of it, position the cursor immediately to the left of the first character you want to have 
deleted. 

Summary of Contents for XND-4D

Page 1: ...XND 4 4 Port Ethernet DMX Node User Manual...

Page 2: ...UM_XND 4 D0 LEN V01 07 DRAFT DOCX 2020 09 22...

Page 3: ...troduction 4 Unpacking 4 Safety Information 5 Device Overview 7 Settings and Menu 10 Status LEDs 25 Screen Saver 26 Firmware Updates 26 Web Interface 27 Technical Data 29 Ordering Information 31 Credi...

Page 4: ...ata to your fixtures from a computer or even from a mobile device Many light controller programs for PC or Mac support Art Net output natively and with the help of XND 4 s DHCP capability you can even...

Page 5: ...damaged defective or wet or if they show signs of overheating Do not expose the device to rain or moisture Do not operate the device if any cover or component is missing damaged or deformed Refer any...

Page 6: ...6 Do not use the device in areas where it is exposed to direct sunlight Do not use the device in areas that are highly inflammable...

Page 7: ...on rack and truss mountable models regular RJ45 socket on XND 4D 6 Port buttons 1 4 These push buttons are used to open the port menu of the corresponding port A port status LED showing status inform...

Page 8: ...supplied with both overload and ground fault earth fault protection Important Only attach or remove a Neutrik powerCON connector while it is connected to the mains to apply or cut power in an emergenc...

Page 9: ...ors with RJ45 connectors or 3 pole box header connectors XLR Connectors RJ45 Connectors Box Header Connectors Each port is individually optically isolated On the XND 4D a box header and a RJ45 connect...

Page 10: ...By keeping the Cancel button pressed for at least two seconds you can always navigate to the Home Screen From the Home Screen the menu is launched by simply pushing the OK button The following notatio...

Page 11: ...rt running in sACN mode the 16 bit sACN universe a number in the range of 1 to 63999 is displayed at the bottom of the screen The left most number corrseponds to the universe of port 1 The universe nu...

Page 12: ...button All following settings can also be changed via web interface on the Network Settings Page as seen on page 28 DHCP Navigate to Home Menu Network DHCP in order to enable or disable DHCP Dynamic H...

Page 13: ...tatic Settings IP Address is set to the primary Art Net IP address 2 X Y Z The values X Y and Z are computed from the device s MAC address Static Settings Netmask is set to 255 0 0 0 Set to Secondary...

Page 14: ...obsolete independent universes functionality is that Art Net 4 support allows an Art Net 4 aware controller to properly understand and if supported by the controller configure the port address of eac...

Page 15: ...nding Text To append or insert text move the cursor to the position where you want to add your text Then push the OK button and select a character to add Confirm your selection by pressing OK Repeat t...

Page 16: ...linking cursor is shown below the currently editable digit Use the encoder to increase or decrease that digit Push the port button corresponding to the port that is being edited to change the digit th...

Page 17: ...rom the network Input1 The port is configured as DMX input and sends data to the network Off The port is turned off A bullet point is shown next to the currently active setting Use the encoder wheel t...

Page 18: ...the same port If more than two controllers send data for the same port the following rules take effect Art Net The first two appeared data streams are merged All following ones are discarded sACN The...

Page 19: ...IP address multicast for sACN Every reachable device in the same subnet can receive the data Unicast DMX data applied to the input port is transmitted to a unicast IP address set by the user Only one...

Page 20: ...e sACN no RDM o Same as sACN Art Net RDM disabled on all ports 1 2 Art Net 3 4 sACN o Art Net RDM is enabled on all ports o All ports are configured as outputs o Ports 1 and 2 are configured to Art Ne...

Page 21: ...i are displayed as decimal numbers Hexadecimal Art Net net Art Net sub net Art Net or sACN universe and Art Net sub uni are presented as hexadecimal numbers with a trailing h e g F3h A bullet point is...

Page 22: ...he device is locked the user will only be able to see the Home Screen see page 10 and the Ethernet Port Status Information see page 25 Since the menu is unavailable while the device is locked the Ethe...

Page 23: ...s enabled Simple Locking Simple locking can be enabled whether a password has been set or not When simple locking is used the user will be asked to press Cancel three times within 3 seconds when attem...

Page 24: ...RDM Disabled on all output ports1 Auto universe label Enabled2 Independent universes Disabled3 Art Net version Art Net 44 All outputs enabled DMX output mode all ports Relaxed5 Art Net universe outpu...

Page 25: ...onds once every 0 2 seconds The DMX ports and the Ethernet port can be selected using the respective port push button Further the DMX ports can also be selected via the menu Home Menu Outputs Output 1...

Page 26: ...n saver is enabled Once the display is turned off it can be turned on again by pushing any button or by turning the encoder wheel by one unit in any direction The screen saver can be enabled or disabl...

Page 27: ...essfully No Update Not receiving any updates on this universe for the last 10 seconds Off The port is currently disabled through settings made by the user No DMX The port is not receiving transmitting...

Page 28: ...view and make changes to any relevant device information Furthermore the factory defaults can be restored from here A detailed description of the device settings can be found on page 21 Firmware Upda...

Page 29: ...29 Technical Data XND 4R XND 4B XND 4D...

Page 30: ...1 4 sACN ANSI E1 31 sACN draft version v0 2 DMX ANSI E1 11 RDM ANSI E1 20 Electrical standard signal ports EIA 485 Dimensions Rack Mountable Models Depth 136 mm 5 35 in Width 482 6 mm 19 in Height 44...

Page 31: ...t notice this list of conditions and the following disclaimer 2 Redistributions in binary form must reproduce the above copyright notice this list of conditions and the following disclaimer in the doc...

Page 32: ...ers using Art Net I or Art Net II the Art Net net must be set to 0 The Art Net net sub net and universe can be combined to a 15 bit port address with values from 0 to 32767 as shown below Bit Digit 14...

Page 33: ...ace Compatible Browsers The web interface was tested with following browsers Browser Version Chrome 80 0 3987 132 Firefox 73 0 1 Safari 13 1 Opera 67 0 3575 53 Edge 44 17763 831 0 Internet Explorer 11...

Page 34: ...warranty of any kind either directly or indirectly and is subject to change without prior written notice Swisson its employees or appointed representatives will not be responsible for any damages to...