Safety  Information  

Consider   the   following   notes   absolutely   when   you   set   up,   connect   and   use   the   ISP.   

This   product   is   not   for   household   use.   Read   this   manual   before   operating   the   device,   follow   the   
safety   precautions   and   observe   all   warnings   in   this   manual.   

Use   this   device   only   in   accordance   with   local   laws   and   regulations.   

Safety  Precautions  

 

Disconnect   the   device   from   AC   power   before   removing   any   cover   or   part,   including   any   

fuse   and   when   not   in   use.   

 

Ensure   that   the   device   is   electrically   connected   to   ground   (earth).   

 

Use   only   a   source   of   AC   power   that   complies   with   local   building   and   electrical   codes   and   

has   both   overload   and   ground-­‐fault   (earth   fault)   protection.   

 

Before   using   the   device,   check   that   the   power   distribution   equipment   and   cables   are   in   

perfect   condition   and   rated   for   the   current   required   of   all   connected   devices.   

 

Isolate   the   device   from   power   immediately   if   the   power   cable   or   the   power   plug   is   in   any   

way   damaged,   defective   or   wet,   or   if   they   show   signs   of   overheating.   

 

Do   not   expose   the   device   to   rain   or   moisture.   

 

Do   not   operate   the   device   if   any   cover   or   component   is   missing,   damaged   or   deformed.   

 

Refer   any   service   operation   not   described   is   this   manual   to   Swisson.   

 

Provide   unrestricted   airflow   around   the   device.   

 

Do   not   operate   the   device   if   the   ambient   temperature   exceeds   55°C   (131°F).   

 

Do   not   modify   the   device   in   any   way   not   described   in   this   manual   or   install   other   than   

genuine   Swisson   parts.   

 

Do   not   attempt   to   bypass   any   fuse.   Replace   any   defective   fuse   with   one   of   the   specified   

type   and   rating   only.   

 

When   suspending   the   device,   ensure   that   the   supporting   structure   and   all   hardware   used   

can   hold   at   least   10   times   the   weight   of   all   devices   suspended   from   them.   

 

When   suspending   the   device,   install   a   secondary   attachment   such   as   a   safety   cable   that   is   

approved   by   an   official   body   such   as   TÜV   as   a   safety   attachment   for   the   total   weight   it   
secures.   The   safety   cable   must   comply   with   EN   60598-­‐2-­‐17   Section   17.6.6   and   be   capable   
of   bearing   a   static   suspended   load   10   times   the   weight   of   the   device.   

 

Make   sure   that   any   external   cover   and   rigging   hardware   is   securely   fastened.      

 

Block   access   below   the   work   area   whenever   installing,   servicing   or   moving   an   overhead   

device.   

 

Do   not   use   the   device   in   areas   where   it   is   exposed   to   direct   sunlight.   

Summary of Contents for ISP-4

Page 1: ...ISP 4 Installation Splitter User Manual...

Page 2: ...2 P DINRAIL ISP 4 USERMANUAL UM ISP D0 LEN V00 03 DOCX 30 Jan 2014...

Page 3: ...3 Index Index 3 Introduction 4 Safety Information 6 Device Overview 7 RDM Protocol Remote Device Management 10 Technical Data 11 Ordering Information 12...

Page 4: ...splitters may prevent harmful voltages applied to a given port from affecting the other ports and damaging the connected equipment The ISP 4R variants work within DMX RDM environments as well as in pu...

Page 5: ...on Splitter is packaged in a cardboard box The following items are included ISP 4X DC TERM The device This user manual 1 pluggable terminal block connector 3 pin for connecting the PSU 2 pluggable ter...

Page 6: ...ture Do not operate the device if any cover or component is missing damaged or deformed Refer any service operation not described is this manual to Swisson Provide unrestricted airflow around the devi...

Page 7: ...n the line termination on and off 3 DMX trough port 4 DMX input 5 Power LED 6 Signal LED Indicates that a signal is being received 7 Error LED Indicates a faulty signal 8 Identify LED ISP 4R only 9 Se...

Page 8: ...ust be supplied by the user Stabilized DC output voltage 10V 48V max 400 mA Power 4 W See page 7 item 1 power input It is not strictly required but highly recommended to properly connect the ground pi...

Page 9: ...d ISP 4R DC RJ45B are configured as isolated transmitters as defined in ANSI E1 11 such that each output port is individually optically isolated meaning that it is totally isolated from the other outp...

Page 10: ...usceptibility to environmental noise RDM Protocol Remote Device Management All ISP 4R models support the RDM protocol ISP 4D models do not support the RDM protocol The ISP 4R models forward incoming R...

Page 11: ...0 mm 3 54 Width 124 5 mm 4 9 Height 56 mm 2 2 Weight 0 4 kg 0 9 lb Ambient temperature 30 C 55 C 22 F 131 F DC power 10V 48V max 400mA Power consumption 4W DMX ANSI E1 11 RDM ANSI E1 20 Electrical sta...

Page 12: ...1 in 4 out ports Input and outputs optically isolated RJ 45 alternative pin configuration 10 48V DC DMX 512 plus RDM Variants 20 10 20 ISP 4R DC TERM DMX RDM splitter for DIN rail installation 1 in 4...

Reviews: