![swissflex uni 12 75K bridge Operating Instructions Manual Download Page 12](http://html1.mh-extra.com/html/swissflex/uni-12-75k-bridge/uni-12-75k-bridge_operating-instructions-manual_1415119012.webp)
12
Operating instructions
EN
Problem
Possible cause
Solution
Remote control or
control system not
working.
No mains supply.
Restore mains connection.
Manual switch or control system defective.
Contact your supplier / stockist.
Control systems
suddenly no longer
travel / move.
Thermoswitch on the transformer may have
been triggered or may be defective.
Leave the control system in the rest position for 20-30 minutes.
Thermal cut-out in the transformer may have
been triggered or may be defective.
Contact your supplier / stockist.
Internal fuse may have been triggered or may
be defective.
Contact your supplier / stockist.
No mains supply.
Restore mains connection.
Supply line (mains and / or manual switch /
auxiliary control system) interrupted.
Check the supply line and restore contact if applicable.
The battery-operated
electric reset function
cannot be activated.
Block battery / block batteries flat.
Check and replace the block battery / block batteries if necessary.
Block battery/batteries not connected.
Connect the block battery / block batteries.
Technical data
Supply voltage: 110–240 Volt / 50-60 Hz
Thrust motors: 6000 N
Supply emergency set-down function:
1x 9 V block battery
Total connected load: 140 W / 6A
Temperature range: + 5 °C to + 40 °C
After a power failure
Before resuming use of the uni 12_75K, press and
hold the button
(5)
, until all sleep areas have reached
the horizontal position and the motors have stopped
moving.
Activating the emergency set-down
Press the «All motors down» button
(5)
on the cable
remote control to reach the horizontal (basic) posi-
tion. The repeated use of the emergency set-down
function puts a lot of strain on the batteries so that
they must be replaced.
Summary of Contents for uni 12 75K bridge
Page 22: ......
Page 23: ......
Page 24: ......
Page 25: ......
Page 26: ...26 Istruzioni d uso IT...
Page 27: ...27 IT Istruzioni d uso...
Page 28: ...Recticel Bedding Schweiz AG Bettenweg 12 CH 6233 B ron www swissflex com 28 05 2015...