Manufacturer's advice
Technical data
Batteries
Technology:
2 x AAA NiMH
Voltage:
1.2 V
Capacity:
400 mAh
Handset operating times/charging times
The operating time of the telephone depends on the capacity of the battery, its age and the way it is used.
(All times are maximum possible times).
Base power consumption
General specifications
Standby time (hours) *
200 * / 110 **
Talktime (hours)
18
Operating time for 1.5 hours of calls per day (hours) *
90 * / 65 **
Charging time in base (hours)
4
Charging time in charging cradle (hours)
4
*
No Radiation
deactivated,
without
display backlight in idle status
**
No Radiation
activated,
without
display backlight in idle status
In standby mode
•
Handset in charging cradle
•
Handset outside charging cradle
approx. 0.6 W
approx. 0.55 W
During a call
approx. 0.65 W
DECT standard
Supported
GAP standard
Supported
No. of channels
60 duplex channels
Radio frequency range
1880-1900 MHz
Duplex method
Time division multiplexing, 10 ms frame length
Repetition frequency of the transmission pulse
100 Hz
Duration of the transmission pulse
370 μs
Channel grid
1728 kHz
Bit rate
1152 kbit/s
Modulation
GFSK
Language code
32 kbit/s
Transmission power
10 mW average power per channel, 250 mW pulse power
Range
Up to 40 m indoors, up to 250 m outdoors
Base power supply
230 V ~/50 Hz
Environmental conditions for operation
+5°C to +45°C, 20% to 75% relative humidity
Dialling mode
DTMF (tone dialling)/PD (pulse dialling)