Swiss HealthPro 100 User Manual Download Page 15

15

Chapter 4

– Using the Control Panel

timer status field

start time

end time

4.4.3  Setting the Daily Timer

The Daily Timer Menu allows the setting of a Timer ON period, which is defined
by a start time and an end time. For the Timer ON period, a fan speed can be
selected in the Timer ON Fan Speed Menu (see 4.4.5). The time outside the
Timer ON period is defined as the Timer OFF period for which the air cleaner
can be switched off or for which a different fan speed can be selected in the
Timer OFF Fan Speed Selection Menu (see 4.4.5).

The timer status field indicates whether the timer function is enabled or
disabled and allows the user to quickly enable/disable the timer e.g. for
holiday.

1.

To reach the Daily Timer Menu from the main display window, press the

Menu

key twice.

2.

Press and hold the 

Enter

key until the cursor starts to flash. 

3.

Press the 

p

key once to activate the timer. 

Note: 

If the start and stop time are identical, the timer cannot be ac tivated.

4.

Press the 

Enter

key to save the timer status setting and to proceed to the

start time.

5.

Select the desired start hour by pressing the 

p

key. 

6.

Press the 

Enter

key to save the start hour and to proceed to the minute

setting. 

7.

Select the desired start minute setting by pressing the 

p

key. 

Note:

The minute settings can only be set in five minute increments.

8.

Press the 

Enter

key to save the start time and to proceed to the stop time

setting.

9.

Select the desired stop hour by pressing the 

p

key. 

10.

Press the 

Enter

key to save the stop hour and to proceed to the minute

setting. 

11.

Select the desired minute setting by pressing the 

p

key. 

12.

Press the 

Enter

key to save the minute setting and to exit the enter mode

Summary of Contents for HealthPro 100

Page 1: ...Swiss Made 105 10 31 40_140113_IN_MA_HP100_EN CN HealthPro 100 User Manual...

Page 2: ......

Page 3: ...danger of dust explosions Do not use this appliance in explosive areas Only use filters and accessories recommended by the manufacturer Do not use outdoors Do not obstruct the air inlet and air outlet...

Page 4: ...ng the Daily Timer 15 4 4 4 Setting the Weekly Timer 16 4 4 5 Timer ON OFF Fan Speed Selection 16 4 4 6 Timer Information in the Control Panel 17 4 4 7 Time Day Setting 17 4 4 8 Filter Life Reset 18 4...

Page 5: ...llutants enter the room air is high or the indoor air quality requirements are stringent the hourly air delivery of the system needs to exceed the room air volume several times To achieve that level o...

Page 6: ...ances a divergence of 10 10m3 h is deemed acceptable Note The air delivery rate refers to the system s initial air delivery which will decrease as filters load up with dust particles Measuring instrum...

Page 7: ...6 Turn the device upside down on a soft and clean surface Place the mounting rail on the purifier s base so that the holes line up with the black connector pins on the base The cut ins should face the...

Page 8: ...a wall or a cupboard In general the more centrally the system is positioned the better the performance Position the system close to a power outlet and make sure that the power cable is positioned in a...

Page 9: ...ures air intake openings on two sides The PreMaxTM filter module consists of frame 1 and the PreMaxTM filter which is fixed inside the frame by four filter clamps The fan assembly comprises two housin...

Page 10: ...everal square meters of tightly pleated HyperHEPA filter media that removes even the tiniest particles 5 Low turbulence low velocity air is returned to the room via the EvenFlow diffuser 3 2 Descripti...

Page 11: ...the front locking arm Several operations can be completed via the electronic control panel including Switching the system on and off Controlling the fan speed and corresponding air delivery rate Chec...

Page 12: ...uced dramatically either due to a reduction in airflow particle filters are clogged or a reduction in filter efficiency gas phase filter is saturated Fan Speed LEDs These LEDs simulate the fan speed t...

Page 13: ...ced by the system in a specific environment are calculated as follows hourly air delivery of the system m3 h air changes per hour ACH air volume of the room m3 N B The air delivery rates at the variou...

Page 14: ...red with an internal memory bank which contains infor mation about the different filters lives under specific conditions of use The Filter Life Monitor makes a calculation of the remaining filter life...

Page 15: ...splay window press the Menu key twice 2 Press and hold the Enter key until the cursor starts to flash 3 Press the p key once to activate the timer Note If the start and stop time are identical the tim...

Page 16: ...tion exits the enter mode 4 4 4 Setting the Weekly Timer The weekly timer allows the activation deactivation of the Timer ON period on certain days of the week In its default setting the timer is enab...

Page 17: ...the Enter key until the cursor starts to flash 3 Select the hour by pressing the p key 4 Press the Enter key to save the hour setting and to proceed to the minute setting 5 Select the minutes by pres...

Page 18: ...e main display window press the Menu key ten times The current display language is displayed 2 To change the display language press and hold the Enter key until the cursor starts to flash 3 Use the p...

Page 19: ...remain airborne for long periods of time This dust group is made up of small combustion particles that are created as the result of combustion processes of automobiles small allergen particles such a...

Page 20: ...to the Fine Dust index 6 Press and hold the Enter key until the cursor appears 7 Press the p key to modify the Fine Dust index to reflect the fine dust pollution levels found in the environment where...

Page 21: ...ible to switch the timer on and off with the remote control To switch the timer on press the Timer Modification key and then the Timer ON key To switch the timer off press the Timer Modification key a...

Page 22: ...a matter of minutes The illustration of the system on the right side of the control panel shows the positions of the individual filters These positions correspond to the actual positions of the filter...

Page 23: ...the arm from its snap in position in the diffuser Disengage the other arm in the same way 3 Pull both locking arms evenly outwards until they snap into place and remain open Access to all filter eleme...

Page 24: ...using For details on how to close the housing please refer to the section 6 3 8 Dispose of the used filter by placing it into the plastic bag in which the new filter is supplied 7 Lift the frame from...

Page 25: ...see the section 6 7 9 Put frame 2 back into the housing and reposition the diffuser For closing refer to the section 6 3 Frame 2 6 6 Discarding Used Filters Used filters can normally be put into the...

Page 26: ...wall mounting of the system where floor space is limited InFlow Complete ducting adapter kit for the creation of positive pressure if placed within the room and negative pressure if placed outside th...

Page 27: ......

Page 28: ...INCEN AG Blumenfeldstrasse 15 CH 9403 Goldach Switzerland www iqair com uk...

Reviews: