background image

 
 
 

Page

 

12

 

3373.501.02

 

Version

 

1.0

 

CONNECTORS

 

DESCRIPTION

 

 

 
 
 

Summary of Contents for Athletics Switcher

Page 1: ...ss Timing LTD Phone 41 32 488 36 11 P O Box 138 Rue de l Envers 1 info swisstiming com CH 2606 Corgémont Switzerland www swisstiming com ATHLETICS SWITCHER OUTDOOR USER S MANUAL 3373 501 02 l Version 1 0 l ...

Page 2: ...right to refuse all guarantees if this condition is not fulfilled If the installation includes a horn be sure to maintain a sufficient security distance from the public Documentation Updates Swiss Timing SA reserves the right to make improvements in the products described in this documentation at any time without prior notice Furthermore Swiss Timing SA reserves the right to revise this documentat...

Page 3: ... 1 3 Single power supply and external battery 4 3 1 4 Double external batteries 4 3 2 Cameras connections 5 3 2 1 Cameras Primary Secondary 5 3 2 2 Cameras Primary Infield Track as Secondary 5 3 2 3 Cameras Primary Secondary Infield Track 5 3 2 4 Cameras Primary Secondary Infield Track Shadow 6 3 2 5 Additional timer 6 3 3 Rear panel description 7 3 3 1 Power 10 30VDC 7 3 3 2 Cameras 7 3 3 3 Cell ...

Page 4: ... 0 5 USB CONNECTION 10 5 1 Install drivers 10 6 CONNECTORS DESCRIPTION 12 7 TECHNICAL SPECIFICATIONS 13 7 1 Mechanical characteristics 13 7 2 Electrical characteristics 13 8 APPENDICE 14 8 1 Index figures 14 8 2 Version history 14 ...

Page 5: ......

Page 6: ......

Page 7: ...mediate photocells at 200m and 1500m Power supply 10 30VDC external PSU 110 240 VAC 15VDC Dedicated keyboard for photocell activation Possibility to connect 3 OSV cameras Data output can be switched between PRY and SDY cameras Switch start measurement command between PRY and SDY wind gauge Compatible with Mistral Boreas wind gauge devices Wind speed and false start ASC data dispatched between PRY ...

Page 8: ...CONNECTIONS 2 1 Connections overview Only one Start StartTime or False start ASC can be connected on the track All unused start systems must be disconnected You may only reconnect start system if necessary 2 2 Front view 2 3 Rear View ...

Page 9: ...ASO Athletics Switcher Outdoor Version 1 0 3373 501 02 Page 3 2 4 Distribution of RS422 data ASC3 False start Windgauge Scoreboard 2 5 Distribution of START FINISH contacts START FINISH ...

Page 10: ... There are several possible cabling solutions and you will find some examples below 3 1 Timing Room connections 3 1 1 Single power supply 3 1 2 Double power supply 3 1 3 Single power supply and external battery 3 1 4 Double external batteries ...

Page 11: ...thletics Switcher Outdoor Version 1 0 3373 501 02 Page 5 3 2 Cameras connections 3 2 1 Cameras Primary Secondary 3 2 2 Cameras Primary Infield Track as Secondary 3 2 3 Cameras Primary Secondary Infield Track ...

Page 12: ...as will record when Finish photocell is activated If MAN is selected both cameras will record when pushbutton is activated 3 2 5 Additional timer An additional timer can be connected to the START and FINISH contacts trough the INFIELD camera connector A specific cable is needed according to the timer model In this configuration select the INFIELD switch in position CELL Do not use pushbutton MAN ...

Page 13: ... supplies are connected to the ASO add an Uninterruptable Power Supply UPS 3 3 2 Cameras 3 cameras can be connected to the ASO unit Primary and Secondary cameras are positioned in the timing room and Infield could be installed in the track or in the control room as Shadow Select CELL if recording is started by FINISH photocell or MAN if started by a pushbutton The pushbutton is connected in the tw...

Page 14: ...5 Galactica Connect the Galactica computer INT131 with the cable 1871 xxx xxx cable length in meters 010 025 Only the running time is transferred same information as track scoreboards 3 3 6 Telephone Connect the telephone unit to the track with the cable 1878 xxx xxx cable length in meters 010 050 100 ...

Page 15: ...mes 200M 400M 1500M are requested connect the Photocell Switcher to the Athletics Switcher A board will help you to select the correct intermediate time according to the race length 4 3 1 Intermediate time 200M or 1500M When the first racer arrives near the intermediate photocell press and hold the intermediate button 200M or 1500M until the racer crosses the photocell then release the button 4 3 ...

Page 16: ... computer and boot to Windows 2 Put the driver CD in the CD ROM then run the PL 2303 driver See Fig 1 and 2 Fig 1 Fig 2 3 Connect Athletics Switcher PRY or SDY with your computer by USB cable 4 Windows will auto detect four new USB devices and start InstallShield Wizard See Fig 3 Fig 3 ...

Page 17: ...s the PL2303 driver will auto assign a COM number from your system 1 2 Remove drivers Use the DRemover98_2k to remove INT131 driver Double click DRemover98_2k If INT131 driver software has already been installed the modify repair or remove the program window will appear then select Remove to clean INT131 driver completely It is necessary to update the driver when INT131 adds new features or functi...

Page 18: ...Page 12 3373 501 02 Version 1 0 6 CONNECTORS DESCRIPTION ...

Page 19: ...Gewicht 3 7 kg 0 6 kg Protection Protection Schutzklasse IP42 indoor use Working temperature Température de fonctionnement Betriebstemperatur 0 C to 50 C Temperature range storage Température de stockage Lagertemperatur 30 to 85 C 7 2 Electrical characteristics Power supply Alimentation Speisung External power supply Athletics Switcher 110 240 VAC 15VDC 10 30VDC Power consumption Consommation élec...

Page 20: ...Page 14 3373 501 02 Version 1 0 8 APPENDICE 8 1 Index figures No table of figures entries found 8 2 Version history Version Modifications since last version 1 0 Initial version ...

Page 21: ...ASO Athletics Switcher Outdoor Version 1 0 3373 501 02 Page 15 NOTES ...

Page 22: ......

Page 23: ...Swiss Timing LTD Phone 41 32 488 36 11 P O Box 138 Rue de l Envers 1 info swisstiming com CH 2606 Corgémont Switzerland www swisstiming com ...

Reviews: