background image

30 

System « WOOSIT » 

Writing the animal owner’s telephone number(s) in the ISO tag 

Our  wish  to  constantly  innovate  and  improve  our  products  has  led  us  to  offer  vets  the  option  of 
personalizing the tag, if they wish, before implanting it in the animal. 
The main technological advance offered by this V8BT reader is that it will allow reading and display of 
data  which  can  be  entered  by  the  vet  in  the  majority  of  the  “tags”  currently  marketed  worldwide, 
provided that they comply with the ISO standard. 

Realtrace has developed a system called “WOOSIT

®

” which is comprised of:

-

A reader /programmer    the PetSCAN RT150

 (1)

 which enables the vet to write additional

information to the “chip” before injecting it into the animal

(2)

.

-

The PetSCAN V8BT which now offers the possibility to read and display the ID number but also

to display additional data recorded by the vet in the memory as the phone number of the owner. 
Due to the low memory capacity available in ISO chips (used up until then) the “WOOSIT”  system is 
limited to the recording of one or two telephone numbers of 16 digits each . The vet and/or the owner 
of the animal may choose these numbers.

 

This system is totally compliant with the ISO 11784/85 standard of 1996 in addition to the new 14223 
standard* (May 2011) concerning the recording of data in advanced transponders.

 

It protects the asepsis of the chip, as the writing of the data is carried out via the cap which protects 
the needle.

 

If the owner prefers this, after the recording of one or two telephone numbers, the memory area used 
for this record can be blocked, making it impossible to delete or subsequently modify this information.

 

With the “WOOSIT” system, finding the owner of an animal will be particularly easy as reading the 
“chip” with the V8BT  will provide the phone  number(s) of the  administrator of the  database  and/or 
the owner of the pet.

 

Naturally,  any  pet  owner  who  does  not  wish  to  use  this  service  can  simply  enter  nothing  in  the 
memory area of the chip, as is currently the case.

 

.

    ID number and phones numbers   

       

Iso Chip 11784/85 compatible with the possibility to write aditionals data 

(FDXB+)

 

(1)Patented

(2)Sous  réserve  que  les  blocks  3/9/10/11/12/13  (EM4305)  ou  9/10/11/12/13/14/15  (EM  4569)  ne  soient  pas

verrouillés par le fournisseur de la « puce ». 

*

L'ISO  14223-1:2011  spécifie  l'interface  hertzienne  entre  l'émetteur-récepteur  et  le  transpondeur  évolué  utilisé

pour  l'identification  des  animaux  par  radiofréquence,  à  compatibilité  ascendante  totale  avec  les  spécifications 

données dans l'ISO 11784 et l'ISO 11785.

   

Summary of Contents for RT100V8BT

Page 1: ...rite additionals data Two phones numbers In out button 1 Mini USB interface LED blue Bluetooth activated LED red charging battery LED green battery charged Display OLED 128 64 pixels Scroll up button 2 Mid button 4 Enter Scroll down button 3 Battery charge level ...

Page 2: ...le Bluetooth pages 6 7 8 The memory of the V8BT page 9 enable the memory page 10 disable the memory page 11 erase the memory page 12 Datas transmissions with a PC pages 13 à 21 RealTrace Terminal pages 22 à 26 Customization of the V8BT displaying and Time out page 28 29 The Woosit system writing a chip page 30 Realtrace Phone pages 31 à 37 ...

Page 3: ...te OLED Keys 4 buttons Indication Battery charge control and Bluetooth Buzzer USB port USB virtual comport bluetooth virtual com port Power supply Lithium battery 1400mAh 3 7V 5 18 Watts hr Dimension 155mm L 82 W 33 H Net weight 155g Charging mode Mini USB Accessories Mini USB cable Product instructions Battery Compliance certifications FCC CE certification Memory Up to 800 ID numbers ...

Page 4: ...English OK 5 seconds Français Français OK 5 seconds Español Español OK 5 seconds Italiano Portugues Deutsch Polish SCAN Italiano OK 5 seconds Portugues OK 5 seconds Deutsch OK 5 seconds Polish OK 5 seconds Synoptic Menu Language ...

Page 5: ...5 Synoptic Menu Scan Synoptic Menu SCAN SCAN After 25 seconds After 60 seconds Reading 20 seconds max No transonder Found FDXB 939 2784879521125 Charging indicator light Scan Button In Out ...

Page 6: ...a security code If your PC need a code enter 1234 Data transmission by Bluetooth or via the USB cable To be able to transmit the tag numbers read or the numbers recorded in the memory maximum 800 via Bluetooth or using the USB cable the user needs to have installed the appropriate driver on his PC This driver can be downloaded free of charge from http www swissplusid com downloads RTDriver zip Onc...

Page 7: ...7 Synoptics Menu Bluetooth Bluetooth Enable Bluetooth enabled Charging indicator light Scan Enable Bluetooth Bluetooth Button IN OUT 1 4 3 2 1 ...

Page 8: ...8 Bluetooth Disable Scan Disable Bluetooth Bluetooth Button IN OUT Scan 1 2 3 4 5 ...

Page 9: ... DUP on the right of the screen This number will not be stored a second time If the reader is switched off the memory function will still be activated when it is switched on again Deactivating the memory The memory can be deactivated via the Memory menu Two cases may arise First case Numbers are recorded in the reader s memory Block diagram Memory 3 In this case you must transmit the list of recor...

Page 10: ...10 Synoptic Menu Memory 1 Memory Enable Charging indicator light Scan Enable the memory M 0 Scan Button IN OUT 1 4 3 2 Press two times ...

Page 11: ...11 Synoptic Menu Memory 2 Memory Disable M 0 Scan Disable the memory No chip registered Scan Button IN OUT 1 2 3 4 Press two times ...

Page 12: ...y 3 M 15 Memory Send M 15 Scan Enable the memory 15 ID numbers registered M 0 Scan Button IN OUT 1 2 3 4 Press twices Sending Press OK to erase Press OK to confirm erase Without pressing after 8 seconds M 15 Scan Erasing 5 6 ...

Page 13: ...P Realtrace Terminal etc which enables the data to be displayed on the computer screen and processed if necessary Serial link use of the Windows Hyperterminal The current version of the PetScan RT100 V8BT transmits the read identifiers to the PC it is connected to either via the USB cable or its wireless link Bluetooth The reader does not wait for any order or acknowledgement from the PC Hardware ...

Page 14: ...he reader offers the user the option of deleting the content of its database at the end of the transmission Format of the frames transmitted to the PC the frame which is transmitted on each reading of a transponder is preceded by a header octet xAA its 4 character registration number in the memory and a separation character Algorithm for calculating aCRC CCITT 16bit control word The C ANSI functio...

Page 15: ...expressed as an polynomial expression such as x 16 x 12 x 5 1 CHECK 0xE5CC This is the checksum for the ascii string 123456789 EXAMPLE http www zorc breitbandkatze de crc html define crc_poly 0x1021 Polynome du CRC CCITT 16Bits unsigned int crc_ccitt16 unsigned char inbuffer unsigned int crc_checksum 0xffff unsigned char ch char i xor_flag while inbuffer 0 ch inbuffer for i 0 i 8 i xor_flag crc_ch...

Page 16: ...16 if xor_flag crc_checksum crc_checksum crc_poly return crc_checksum ...

Page 17: ... cases with other information such as the communication speed the form of the data transmitted etc As regards the V8BT it is possible that the right port will be automatically assigned by the PC to the application software but it is also quite likely that you will have to choose it yourself from all the ports offered to you You can of course try them one after the other but in some cases the PC s ...

Page 18: ...18 Then select Device Then Select Device Manager Then select Ports com et LPT Click Cliquez Click ...

Page 19: ...19 The number of the Com port is shown Number of Port Com connected with the V8BTBT ...

Page 20: ...20 How to know what USB port the V8BT is connected to Windows 7 8 Select as shown below Then select System Click Click ...

Page 21: ...evice Manager Then select Port COM et LPT The number of the Com port is shown The screens may be a little bit differents It depends of the Windows version Click Click Com3 is the number of Port connected to the V8BTBT ...

Page 22: ...th technology operates as well as the Windows operating system The use of a lithium ion battery has provided a significant increase in the autonomy of the reader several thousand uses Therefore you can adjust the auto power off period as required 2 5 10 or 30 minutes or if you prefer you can switch off the time out altogether not recommended This setting can be implemented the same way if Bluetoot...

Page 23: ...lete and Exit functions are classic The Linking an application function when selected allows you to link the data sent by the reader to the PC to a Windows application Word Excel etc and simultaneously display in the RealTrace Terminal window If you want to save an Excel file a number or a list of numbers stored in the memory of the reader you must select Linked to an application You then have fiv...

Page 24: ...24 Menu Realtrace Terminal Language Selection Keyboard Type Communication Port Selection ...

Page 25: ...25 Linking an application Selecting application after the 5 second delay Application open within 5 seconds Excel ...

Page 26: ...26 Connect Simple view only ISO number ...

Page 27: ...27 Showing all data ...

Page 28: ...s message could be your company name customer name date of sale or other text of your choice given that you have two 16 character lines Upon starting the reader the V8BT displays the recorded message for 4 seconds 2 Setting the reader power timeout V8BT timeout The use of a lithium ion battery has provided a significant increase in the autonomy of the reader several thousand uses Therefore you can...

Page 29: ...date as the validity of the start of the guarantee period 4 Enter the fields on the screen and confirm Write The communication port is configured automatically The new settings will be implemented upon the next launch of the V8BT reader PS Customizing each reader takes a few seconds ...

Page 30: ...compliant with the ISO 11784 85 standard of 1996 in addition to the new 14223 standard May 2011 concerning the recording of data in advanced transponders It protects the asepsis of the chip as the writing of the data is carried out via the cap which protects the needle If the owner prefers this after the recording of one or two telephone numbers the memory area used for this record can be blocked ...

Page 31: ...possible to update the numbers by overwriting the chip implanted in the animal The write and read distance for additional data on the chip by the V8BT reader is about 7 to 9 centimetres that is slightly less than the distance for reading the ISO number 10 to 12cm The PC program allows the entry of two 16 digit sequences i e two phone numbers We advise to register these numbers indicating the ISO c...

Page 32: ...e Phone software Phase 1 Connecting the V8BT and opening the RealTrace Phone program Connect the V8BT to the PC using the USB cable turn on the reader display shows Read and then the computer monitor click on the icon and the following window will open on the screen It is possible that when connecting the V8BT to the PC that an update the software resident in the V8BT is carried out automatically ...

Page 33: ...um the reader is programmed to turn off after two minutes if no key has been activated during this time So if it is off turn it on and read a chip either through the needle or on the animal During this reading it is not necessary for the V8BT to be connected to the PC The number of the chip appears on the screen on first line of the reader possibly followed by one or two lines of numbers correspon...

Page 34: ...s one if the chip already had phone numbers Confirm by clicking OK Phase 5 Enter one or two phone numbers using the PC Depending on what you want to do you will either need to enter the phone numbers you want to write into the chip or modify those already saved to it ...

Page 35: ...g the USB cable or Bluetooth A message informs you that you can disconnect the reader from the PC to write to the chip This disconnection is not essential if you want to write to the chip in the needle but is advisable if you want write to a chip already injected into an animal Phase 6 Data entry by V8BT At the same time as the message appears on the PC the V8BT display indicates The reader seeks ...

Page 36: ... found the chip it must write Back to Main Menu We recommend that you re read the injected chip to verify that the data has been recorded given that if the entry has been done correctly in the chip V8BT displays the following message Very often this happens when one or more memory blocks needed to record phone numbers are closed in the chip so it is impossible to write Or You tried to write into a...

Page 37: ...s on the In Out button will shutdown the reader with two beeps Send the reader back to After Sales 3 A message whether or not intelligible remains displayed Pressing buttons has no effect The program has frozen In this case you need to disconnect the battery very carefully without pulling on the wires and wait a few seconds before re connecting it 4 The V8BT will not switch on even after charging ...

Reviews: