background image

633 893 - 11.08.2015 / ETA / 00

Time-Out after 

15 seconds:

Back to the mode

„Date“

(Display „analog/

digital“ in accordance

with the last choice).

- 1 sec

Confirms recorded
data, quit the settings
menu.
(Display stops
 flashing)

+ 1 sec

6

- 1 min

Selection
„second“ 

+ 1 min

5

- 1 h

Selection
„minute“ 

+ 1 h

4

Selection
mode
„Settings“
(Display flashes) 

3

During the last
5 seconds, the
display „t1“
flashes and „beeps“.

RESET

STOP

2

START

1

I

TIMER

The split-time total is not reset so that two different times that are very close together can be measured.

5

Reset to zero

7

5

STOP TOTAL 

(Display Stop      )

6

4

STOP Splitt (display Split      ) 

5

Splitt

4

Run

3

Splitt

2

START

1

H

TIMING MODE  (SPLITT)

SPLIT-TIME or INTERMEDIATE TIME function

Reset to zero

5

STOP 

Read

4

RUN

3

STOP 

Read

2

START

1

G

TIMING MODE  (ADD)

ADD function

Time-Out after 

15 seconds:

Back to the mode

„Date“

(Display „analog/

digital“ in accordance

with the last choice).

+ 1 day

Confirms recorded data,
quit the settings menu

+ 1 day

4

+ 1 month

Selection
„day“

+ 1 month

3

+ 1 year

Selection
„month“ 

+ 1 year

2

Display
flashes

1

Date
(mode 12h)
(MM.DD.YY)

Date
(mode 24h)
(DD.MM.YY)

F

CORRECTION THE DATE (perpetual calendar)

Time-Out after 

15 seconds:

Back to the mode

„Date“

(Display „analog/

digital“ in accordance

with the last choice).

- 1 min

Quit mode
settings

+ 1 min

4

- 1 h

Selection
„minute“ 

+ 1 h

3

Long pressure of
pushbutton A:
start mode
settings

2

Pressure of
pushbutton A
(display flashes)

1

E

CORRECTION TIME “T2”

Time-Out after 

15 seconds:

Back to the mode

„Date“

(Display „analog/

digital“ in accordance

with the last choice).

Quit mode settings

Seconds „00“ and
quit mode settings

Quit mode settings

5

- 1 min

Selection
„second“ 

+ 1 min

4

- 1 h

Selection
„minute“ 

+ 1 h

3

Long pressure of
pushbutton A:
start mode
settings

2

Pressure of
pushbutton A
(display flashes)

1

D

CORRECTION TIME “T1”

Summary of Contents for SM34054

Page 1: ...he digital display also shows the absolute and relative atmospheric pressure in hectopascal More information can be found in section M Altimeter The altimeter is an innovative function that shows the current height above sea level The altimeter should be recalibrated regularly to ensure a precise altitude measurement Set the altimeter to the effective height of a known point and repeat this proced...

Page 2: ...hes Activating the correction mode Pressure of pushbutton C next sub menu Navigating between sub menus Pressure of pushbutton B next menu Double pressure previous menu Navigating between menus Parking to the nearest position 09 15 h or 03 45 h or Pressure of pushbutton B Parking hands and activation navigation Activating the navigation End of energy E O E End of life E O L 2 Times local journey ti...

Page 3: ...emperature 7 Selection mode Weather relative Weather absolute 6 1 Selection mode Weather absolute Selection mode Temperature Weather relative 6 Selection mode Altitude Altitude diffe rence meter OPTION 5 1 Selection mode Altitude difference meter OPTION Selection mode Weather relative Altitude 5 m 4275 m Selection mode Alarme 1 Alarme 2 4 1 Selection mode Alarme 2 Selection mode Altitude Alarme 1 ...

Page 4: ...me Out after 15 seconds Back to the mode Date Display analog digital in accordance with the last choice 1 day Confirms recorded data quit the settings menu 1 day 4 1 month Selection day 1 month 3 1 year Selection month 1 year 2 Display flashes 1 Date mode 12h MM DD YY Date mode 24h DD MM YY F CORRECTION THE DATE perpetual calendar Time Out after 15 seconds Back to the mode Date Display analog digi...

Page 5: ...d over the elapsed time 5206 m 3 Selection display of altitude diference Display Elapsed time rum time or stopped time 3 days 18 hours 55 minutes 2 Selection display of altitude difference meter display changes every 3 seconds 1 N ALTITUDE DIFFERENCE METER OPTIONAL m Time Out after 15 seconds Back to the mode Date Display analog digital in accordance with the last choice Confirms recorded data qui...

Page 6: ...th South noSET Possible settings No Set Standard atmospheric model fixed temperature at sea level 15 C North T temperate M mediterranean A arid tr tropical P polar South T temprerate M mediterranean A arid tr tropical Selection mode Sync Climate zone Quit mode EcoBatt Quit mode EcoBatt Quit mode EcoBatt Navigation sub menus Quit menu Option Long pressure start mode EcoBatt Selection mode climate z...

Reviews: