- 22 -
8.Troubleshooting
8.1 Error code display on wire controller
Malfunction
Error
code
Reason
Solution
Inlet water temperature sensor
failure T1
PP01
1. The sensor in open or short
circuit
2. The wiring of sensor is loose
1. Check or change the sensor
2.Re-fix the wiring of the
sensors
Outlet water temperature sensor
failure T2
PP02
1. The sensor in open or short
circuit
2. The wiring of sensor is loose
1. Check or change the sensor
2.Re-fix the wiring of the
sensors
Heating piping sensor failure
T3
PP03
1. The sensor in open or short
circuit
2. The wiring of sensor is loose
1. Check or change the sensor
2.Re-fix the wiring of the
sensors
Gas return sensor failure
PP04
1. The sensor in open or short
circuit
2. The wiring of sensor is loose
1. Check or change the sensor
2.Re-fix the wiring of the
sensors
Ambient temperature sensor
failure T5
PP05
1. The sensor in open or short
circuit
2. The wiring of sensor is loose
1. Check or change the sensor
2.Re-fix the wiring of the
sensors
Exhaust piping sensor failure
T6
PP06
1. The sensor in open or short
circuit
2. The wiring of sensor is loose
1. Check or change the sensor
2.Re-fix the wiring of the
sensors
Antifreeze protection in Winter
PP07
Ambient temperature or water
inlet temperature is too low
Normal protection
Low ambient temperature
protection
PP08
1.Beyond the scope of using
environment
2. Sensor abnormality
1. Stop using, beyond the scope
of using
2.Change the sensor
Piping temperature too high
protection under cooling mode
T3
PP10
1. Ambient temperature is too
high or the water temperature is
too high in cooling mode
2. Refrigeration system is
abnormal
1. Check the scope of using
2. Check refrigeration system
T2 water temp. Too low
protection under cooling mode
PP11
1. Low water flow
2. T2 temperature sensor
abnormal
1. Check filtration pump and
waterway system
2. Change T2 temperature
sensor
High pressure failure TS4
EE01
1. Ambient temperature is too
high
2. Water temperature is too high
3. Water flow is too low
Fan motor speed is abnormal or
fan motor has damaged
1. Check the water flow or
filtration pump
2. Check the fan motor
3. Check and repair the piping
system
Summary of Contents for 07iPS
Page 1: ...Swimming Pool Heat Pump User and Service Manual...
Page 2: ......
Page 5: ...3 Model Swimmax 11iPS Swimmax 17iPS Model Swimmax 20iPS Swimmax 25iPS...
Page 6: ...4 Model Swimmax 30iPS...
Page 18: ...16 Connection to pilot the water pump Dry contact timer connection Dry contact pump connection...
Page 32: ...30 9 Exploded Diagram 7 Exploded Diagram Mode Swimmax 07iPS...
Page 34: ...32 Model Swimmax 11iPS Swimmax 17iPS...
Page 36: ...34 Model Swimmax 20iPS Swimmax 25iPS...
Page 38: ...36 Model Swimmax 30iPS...
Page 42: ...40...
Page 44: ...42 4 Parameter checking and setting Click Parameter then enter the password 0757...
Page 48: ...46...
Page 49: ...47...
Page 50: ...A0207SMIR305...