- 18 -
7.2.4
button
Press
for 2 seconds to enter secondary page.
Press
and
to select the functions and press
to enter.
7.2.5
Heating/Cooling/Auto mode
Select
and press
to enter, press
and
to choose Heating/ Cooling/ Auto mode, press
again to exit. The default mode is Heating mode.
Note:Under Automatic mode, it is useless to set parameter P1 .
Operation logic of Auto Mode:
T1=Water inlet temperature /Tset= set temperature=28
℃
NO
Condition
Current working
Status
Water inlet Temperature
Working mode
1
When the heat
pump starts
Startup
27
℃
≤T1<29
℃
Running heating mode
When the heat
pump is running
Heating mode
T1≥29
℃
, last for 3 minutes
Standby
Standby
T1≥30
℃
It switches to cooling
mode
Cooling mode
T1=28
℃
, last for 3 minutes
Standby
Standby
T1≤27
℃
, last for 3 minutes
It switches to heating
mode