background image

4

HOW TO USE:

Prior to setting up the filter system, ensure that the pump is off, as failure to do so will cause 

spider valve to malfunction and damage top mount valve. Pump must be off anytime valve 

handle is depressed and moved to any of the various functions.

 

1

  Inspect all that connections have been made correctly and are secure. 

2

  Depress top mount valve handle and rotate to BACKWASH position. 

3

  Prime and start pump according to pump instructions. 

 

NOTE: ALL SUCTION AND DISCHARGE VALVES MUST BE OPEN WHEN STARTING THE SYSTEM.

  

FAILURE TO DO SO COULD CAUSE SEVERE PERSONAL INJURY. MAKE SURE THE FILTER VESSEL IS

  

FILLED WITH WATER BEFORE STARTING UP THE PUMP OR IT WILL CAUSE THE DAMAGE TO PUMP. 

4

  Once water flow is steady out the waste line, run the pump for at least 2 minutes. The initial

 

back-washing of the filter is recommended to remove any impurities or fine sand particles in the

  

sand media. 

5

  Turn pump off and set valve to RINSE position. Start pump and operate until water in sight glass is

  

clear. . . about 1/2 to 1 minute. Turn pump off, set valve to FILTER position and restart pump. Your

 

filter is now operating in the normal filter mode, filtering particles from the pool water. 

NOTES: 

1

  Note the initial pressure gauge reading when the filter is clean. (It will vary from pool depending

 

upon the pump and general piping system). As the filter removes dirt and impurities from the pool

  

water, the accumulation in the filter will cause the pressure to rise and flow to diminish. When the

 

pressure gauge reading is 8-10 PSI (0.55-0.69 BAR) higher than the initial “clean” pressure you noted,

 

it is time to backwash (clean) the filter. 

2

  IMPORTANT: To prevent unnecessary strain on piping system and valves, always shut off pump

 

before switching filter control valve position. 

3

  To prevent damage to the pump and filter and for proper operation of the system, clean pump

 

strainer and skimmer baskets regularly. 

FILTER CONTROL VALVE FUNCTIONS:

Filter- Set valve to FILTER for normal filtering. Also use for regular vacuuming. 

Backwash- For cleaning filter. When filter pressure gauge rises 8-10 PSI (0.55-0.69 BAR) above start-up 

(clean pressure): 

Stop the pump, set valve to BACKWASH. Start pump and backwash until water in sight glass is clear. 

Approximately 2 minutes or less; depending on dirt accumulation. Proceed to RINSE. 

Rinse – After backwashing, with pump off, set valve to RINSE. Start pump and operate for about 1/2 to 1 

minute. This ensures that all dirty water from backwashing is rinsed out of the filter to waste, preventing 

possible return to the pool. Stop pump, set valve to FILTER and start pump for normal filtering.

Waste-To bypass filter for draining or lowering water level and for vacuuming heavy debris directly to 

waste. 

Re circulate-Water is re-circulated through the pool system; bypassing the filter. 

Closed- Shuts off flow from pump to filter. 

 MODEL NO:  FLOW RATE 

MAX   

FILTER AREA 

MEDIA REQUIRED

   

    PRESSURE     TYPE 

AMOUNT

 

 

GPM M3/H  PSI BAR ft2 

m2 

Filter Sand* 

LBS 

KG

 
71610, 72228  40 

50 

3.5 

1.25 

0.12 

0.018-0.022 in. 

100 

45

 71915, 72229  49 

11 

50 

3.5 

2.0 

0.19 

0.45-0.56 mm 

175 

79

 72220,  72268  52 

11.8 

50 

3.5 

2.64 

0.24 

0.018-0.022 in. 250  113

 72420,  72230  62 

14 

50 

3.5 

3.14 

0.29 

0.018-0.022 in. 300  136

SPECIFICATIONS:

Reviews: