background image

3

Insert the laterals and turn 90°clockwise. 

After hearing the locking sound, the lateral is well installed. 

Please refer to the following picture on the right. 

3

  Check that the air release hose 

         (Part# 5 / Item# 71624, 71924, or 72224; on Pg. 5). 

         is fixed well on the body of lateral holder, and

         that the other end of the air release hose is out of 

         the sand. DO NOT embed the air release hose in the sand. 

4

  To eliminate stress on the laterals, fill the filter vessel with 

        enough water to provide a cushioning effect when the

        filter sand is added. 

5

  Temporarily install the Sand Deflector. This is the included piece of clear plastic designed to fit on 

        the top of the sand tank and center, stand pipe (Part# 4 / Item# 71603, 71903, or 72203; on Pg. 5). 

        It is used to prevent sand from entering the pipe when adding sand to the filter tank. 

        (PLEASE NOTE: Be sure to remove and store deflector in safe place; before connecting the top 

        mount valve)

6

  Carefully pour the sand into the filter vessel and make sure to prevent sand from entering the stem

 

pipe. Please pour the quantity of sand according to the filter tank label. 

7

  Ensuring that the filter top mount valve is free of sand residue, put the O-ring on the top valve 

        mount and then install the valve on the filter vessel. Place the top mount valve on the filter tank so 

        that the port labeled ‘PUMP’ is facing the pump (PLEASE NOTE: This is the port  with raised 

         lettering that says ‘PUMP’; to the right side of the port). Make sure that the stem pipe had fixed 

        well with the top valve mount, and tighten the flange clamp to affix the valve. NOTE: The flange 

        clamp should be well affixed. A poorly affixed clamp can cause injuries!

8

  Using screws from the pump hardware pack, affix the pump to the base. Please reference the pump

 

installation instructions to operate the pump. 

9

  Apply Teflon tape (included) to the smaller diameter male threaded side of the white double-male threaded 

        adaptor (part# 10 / 71626; on Pg 5). Attach this adaptor to the port (on the top mount valve) that only has 

        internal ‘female’ threading.

10.  Adjust the valve position and use the white PVC hose, with installed union nuts, and O-rings (Part #11/ Item 

        #s 71607, 71907, or 72207; Pg 5) along with white double ‘male-threaded’ adaptor (attached in step# 9), to 

        connect the valve to the pump.

11.  Apply Teflon tape (included) to both threaded hose adaptors and attach one to the port that has raised 

        letters that say ‘RETURN’ (on the side; by threading). Connect the included 1.5” x 6’ hose from the top mount 

        valve to the pools return (inlet jet). This is one of the two ports that has both internal and external threading. 

        Attach the 2nd threaded hose adaptor to the female threaded opening on the front of the pump. Connect 

        the 2nd (included) 1.5” x 6’ hose from the installed adaptor on the pump to the pools thru-wall skimmer. 

12.  The final port is used to connect the drain / outlet / waste hose (NOT INCLUDED).  This port has raised letters 

        that say ‘WASTE’ (on the side; by threading).

13.  Remove, thumb-screw plug, from the top mount valve, that is located on the opposite side from the ‘PUMP’ 

        port. Apply Teflon tape (included) to the male threads on the provided pressure gauge 

       (part# 15 / 8961; on Pg 5). Attach pressure gauge to the top-mount valve; where thumb screw plug was  

        removed.

INSTALLATION NOTES:

1

  Make sure the filter is operating under normal working pressure. Use a pressure control valve when

  

the system pump is operating. 

2

  If the pump position is higher than the water level, it requires installing a back water control valve.

3

  If the pump position is lower than the water level, it requires installing an isolation valve. 

 

Incorrect filter position can interfere or stop water return. 

4

  For maximum water flow, use as few hose connections as possible & keep hose bending to a minimum.

5

  Ensure solvents are not excessively applied to fittings as this could run into O-ring and create sealing

 problems.

6

  Do not over tighten fittings or adapters.