11. Introduction of the bottled gas regulation
Regulation (EU) no. 517/2014 of 16/04/14 on fluorinated greenhouse gases and the repealing of
regulation (EC) no 842/2006
Leak checks
Operators of equipment that contains fluorinated greenhouses gases in quantities of 5 tons of CO
2
or more that is not contained in foam, must ensure the equipment is checked for leaks.
Equipment that contains fluorinated greenhouse gases in quantities of 5 tons of CO
2
or more, but
less than 50 tons of CO
2
must be a checked a minimum of every 12 months.
Image of the equivalent CO
2
(CO
2
load in kg and tons).
CO
2
load in kg and tons
Frequency of testing
From 2 to 30 kg load = from 5 to 50 tons
Every year
Annual inspection obligation concerning Gaz R 410a, 2.39kg equivalent to 5 tons of CO
2
Training and certification
The operator of the relevant application shall ensure that the relevant personnel have obtained
the necessary certification, which implies appropriate knowledge of the applicable regulations and
standards as well as the necessary competence in emission prevention and recovery of fluorinated
greenhouse gases and the safe handling of the relevant type and size of equipment.
Record keeping
1. Operators of equipment which is required to be checked for leaks, must establish and maintain
records for each part of such equipment specifying the following information:
The quantity and type of the fluorinated greenhouse gases that are installed.
Quantities of fluorinated greenhouse gases added during installation, maintenance or servicing
or due to leakage.
Whether the quantities of installed fluorinated greenhouse gases have been recycled or reclai-
med, including the name and address of the recycling or reclamation plant, and where appropri-
ate any certificate number.
The quantity of the fluorinated greenhouse gases that are recovered
The identity of the company which installed, serviced, maintained and where applicable repai-
red or decommissioned the equipment, including, where applicable, the number of its certifica-
te.
The dates and results of the checks carried out.
If the equipment was decommissioned, the measures taken to recover and dispose of the fluori-
nated greenhouse gases.
2. The operator must store the information for at least five years. Subcontractors who perform ac-
tivities for operators must keep copies of the information for at least five years.
Summary of Contents for ECO 1093
Page 19: ...MV 1093 9 2018 All rights reserved Swim Fun Scandinavia ApS 19...
Page 34: ...34 MV 1093 9 2018 All rights reserved Swim Fun Scandinavia ApS...
Page 49: ...MV 1093 9 2018 All rights reserved Swim Fun Scandinavia ApS 49...
Page 64: ...64 MV 1093 9 2018 All rights reserved Swim Fun Scandinavia ApS...
Page 79: ...MV 1093 9 2018 All rights reserved Swim Fun Scandinavia ApS 79...
Page 94: ...94 MV 1093 9 2018 All rights reserved Swim Fun Scandinavia ApS...
Page 109: ...MV 1093 9 2018 All rights reserved Swim Fun Scandinavia ApS 109...
Page 124: ...124 MV 1093 9 2018 All rights reserved Swim Fun Scandinavia ApS...
Page 126: ...126 MV 1093 9 2018 All rights reserved Swim Fun Scandinavia ApS...
Page 127: ...MV 1093 9 2018 All rights reserved Swim Fun Scandinavia ApS 127...