Equipment Details
To reset the overheating protection, let the
heater cool down, slide cover on power
electronics (13) upwards and push in the red
button.
IMPORTANT OPERATING NOTES
Warning: Repairs may only be carried
out by an expert!
- A new O-ring must always be installed
after dismantling the exhaust duct!
- Always use original Truma spare parts
for maintenance and repair work!
1. The integrity and tight fit of the exhaust
gas double duct must be checked
regularly, particularly at the end of long
trips. Also check the mounting of the
appliance and the cowl.
2. Following a blow-back (misfire) always
have the exhaust gas system checked by
an expert!
3. Always keep the cowl for the exhaust
duct and combustion air intake free of
contamination (slush, ice, leaves etc.).
4. The liquid gas burner operates fan-
supported, which ensures trouble-free
function even when on the move.
National restrictions must be observed
with regard to operation when on the
move.
5. The installed temperature limiter shuts off
the gas supply if the appliance becomes
too hot. Therefore do not shut the warm
air outlets and the opening for the
returning circulating air.
TECHNICAL DATA
Type of gas:
Liquid gas (propane/butane)
Operating pressure:
30 mbar
Water contents:
12 Litres
Heating up time from approx. 15°C
to approx. 60°C:
Summer-/gas operation: approx. 35 min.
Summer-/electrical operation (1800 W):
approx. 45 min.
Winter mode: approx. 60 min. upward
(depending on the heat output)
Water pressure:
max. 2.8 bar
Rated thermal output:
Liquid gas: 2000 W, 4000 W, 6000 W
Electrical: 900 W, 1800 W
Gas consumption:
170 - 490 g/h
Air delivery volume
max. 287 m3/h (free-blowing without
warm-air duct)
Current input at 12 V:
water heater: 0.2 – 5.9 A
Heating up of water heater: 0.4 A
Stand-by: 0.001 A
Current input of electrical safety/drain
valve at 12 V:
0.035 A
Current input of 230 V:
900 W (3.9 A) or 1800 W (7.8 A)
Weight:
approx. 18.7 kg (without water
contents)
ABG test mark:
S 301
Declaration of conformity:
The Trumatic C 6002 EH heater has been
tested by the DVGW and complies with the
EC gas device directive 90/396/EEC, the
EMC directive 89/336/EEC, the low voltage
directive 73/23/EEC and the associated EC
directives, standards and technical
specifications. The CE product identification
number for EU states is:
CE-0085AS0122.
EEC Type Approval:
e1 022499
62
Summary of Contents for 2005 MH
Page 1: ...Quality with Style Swift Motorhomes Owner s Handbook...
Page 4: ...THE MOTORHOME CODE Code of Conduct 2 The Country Code 4 The Coastal Code 4...
Page 14: ...EN ROUTE Spare Wheel Removal 12...
Page 16: ...SAFETY SECURITY Fire 14 Ventilation 14 Escape Paths 14 Children 14 Security 14...
Page 19: ...ARRIVAL AT SITE Positioning the Motorhome 18...
Page 25: ...Connecting Services 23 Typical gas schematic drawing...
Page 97: ...Equipment Details 95 Fig 1 Front Plate Fig 2 Connection Fig 3 Wiring Diagram...