53
12.8 Trickle vents
Care and maintenance
The slots on the external hood/grille should
be kept clean and free from obstruction, use a
vacuum cleaner and/or small soft brush. The
vents may be cleaned with a damp cloth only,
do not use solvent or abrasive cleaners.
i
Note:
Make sure that you follow all the
recommendations and cautions supplied with
the product.
12.9 Repairs
On white profiles only, stains and scratches
can be removed by sanding and polishing. Use
a 320/400 grit sanding disc and polish using
a sisal rotary brush to bring back the surface
finish.
i
Note:
It is important that you achieve a
smooth even finish before beginning the
polishing stage.
On wood grain surfaces, care should be taken
when cleaning. Any white areas showing as a
result of damage or cleaning can be retouched
using a wood grain marker pen.
If you have a breakage or a crack in the glass,
please contact your nearest glazier. Handle
any broken glass with care and dispose of with
safety of others in mind.
12.10 Kitchen and bathroom
Toilet/shower room
Thermostatic mixer valve (shower)
The Thermostatic Mixer Valve accurately
controls the temperature of water for showering
and will maintain the pre-set temperatures if the
water pressure varies when other appliances
are used. This significantly reduces the risk of
scalding when showering.
CAUTION:
All Thermostatic Mixing Valves
(TMV’s) must be carefully protected against
frost damage and should be removed or
correctly drained down during months in
which frost may occur.
Function
Hot and cold water entering the valve is mixed
to a temperature pre-selected by the user
or installer which is achieved by a thermally
sensitive mechanism within the valve that
proportions the amount of hot and cold water
entering it. The mechanism then automatically
compensates for any variations in supply
pressures or temperatures to maintain the pre-
selected temperature.
i
Note:
In the event of cold water supply
failure, the thermostatic mixing mechanism
will automatically shut down the flow to
prevent discharge of dangerously hot water.
Operating pressure:
Dynamic pressure:
Min: 0.5 Bar
Advisable: 1 Bar
Max: 5 Bar
Static pressure:
Max: 10 Bar
Valves operating outside the above conditions
of use cannot be guaranteed to operate as Type
2 valves.
The valve is designed for use as a high-pressure
valve and is tested against BS EN 1111.
General Care
Summary of Contents for Biarritz Lodge 40x13-2 2020
Page 8: ...9 Warranties 10 AfterSales 12 Swift Connect Direct 12 WARRANTY AND AFTER SALES SUPPORT...
Page 18: ...19 Siting Figure 4 Typical Support and holding down points Twin unit...
Page 19: ...20...
Page 20: ...21 Fire precautions 22 Emergency shut off points 23 GENERAL SAFETY ADVICE...
Page 23: ...24...
Page 29: ...30...
Page 30: ...31 Mains electricity and wiring 32 Bulbs 33 MAINS ELECTRICITY WIRING...
Page 33: ...34...
Page 36: ...37 APPLIANCES...
Page 38: ...39 COOKING...
Page 40: ...41 BLINDS...
Page 42: ...43 Pull out sofa bed 44 Bunk beds 44 BEDS...
Page 57: ...58...
Page 58: ...59 Protecting your RPH and possessions 60 SECURITY...
Page 60: ...61 Winterisation 62 Condensation 63 WINTERISATION...
Page 64: ...65 External dimensions 66 Model names berths and bed sizes 67 TECHNICAL INFORMATION...
Page 78: ...79 Single Unit Generic Gas Technical info...
Page 79: ...80 Single Unit Generic Lighting Technical info...
Page 81: ...82 Twin Unit Generic Lighting Technical info TWIN LODGE SCHEMATIC 2020...
Page 82: ...83 Technical info CO AX Schematic LOUNGE OR...
Page 85: ...86 Notes...