MAINTENANCE
The importance of maintenance
Proper maintenance is essential for safe,
economical, reliable, and environmentally friendly
operation.
Failure to properly maintain the DC power unit, or failing
to correct a problem before operation, could result
in a significant malfunction. Some malfunctions can
cause serious injuries or death. Always perform a pre-
operation inspection before each operation and correct
any problems.
Schedule
Regular service
period (1)
Item
Each day
when used
Every 5
years or
500 hrs
Exterior covers
Check
o
Switches (if applicable)
Check
o
LED (if applicable)
Check
o
Power cables
Check
o
Wires harness
Check
o(2)(4)
Battery fastener
Check
o
Replace
o
o(2)
Rubber support, power
unit
Check
o
Replace
o(2)
Battery hook
Check
o
Replace
o(2)
Rubber mount, power
unit
Replace
o(2)
Stopper bolt, power unit
Replace
o(2)
Stopper rubber, power
unit
Replace
o(2)
Drain hole, power unit
Clean
o(2)
Set speed, power unit
Check
When required(3)
V-belt Drive,tension
Check
o
V-belt, condition
Check
o(4)
Rubber dampers
Check
o(4)
(1) Perform at every indicated time or operating hours
interval, whichever comes first.
(2) These items should be serviced by your servicing
dealer, unless you have the proper tools and are
mechanically proficient. Consult your servicing dealer.
(3) Set speed is set to 3600 min‐1(rpm) (rated speed).
If the DC power unit makes an unusual sound, have it
inspected by your servicing dealer.
(4) Replace if necessary.
For detailed instructions about V-belt, see
”SERVICE” on
page 18
.