Set the power roof ventilator’s three speeds
to attain the right air flow. The factory set
control voltages are Away = 2 V, Home = 5 V,
Boost = 8 V.
Speed settings:
• To activate setting mode, press fan speed
and lighting ( + ) simultaneously and
hold for approximately 5 seconds.
• Setting mode is selected with the fan
speed button . The fan speed indication
shows which mode is being set. N.B.!
The fan speed mode can only be set from
lower to higher, for example, the Away
mode’s speed cannot be higher than Home
mode.
• The control voltage is increased with the
lighting button and is lowered with the
damper function button . The selected
control voltage is indicated as follows:
• The settings are saved by pressing and
holding the lighting button for appro-
ximately 5 seconds. If the settings are not
saved or the cooker hood buttons are not
touched for ten minutes the cooker hood’s
settings return to normal mode and the set
values are not saved.
Not lit
Short flash
Long flash
Lit
1 V
2 V
3 V
4 V
5 V
6 V
7 V
8 V
9 V
10 V