unit can then be secured into position by screwing in
the locking screws to their end positions.
1
2
3
1. Suspension plate
2. Locking hooks
3. Lock screw
2.1.3 Installation of the cooker hood directly on
the ventilation unit
Swegon CASA Jazz cooker hood can be connected
directly below the ventilation unit. In this case, a two-
socket socket is required. Make sure that the spacing
between the cooker hood and cooker corresponds with
local regulations.
Connect the control and power cables that come out
of the bottom of the ventilation unit to the connector
on the cooker hood. Secure the cooker hood to the
ventilation unit with the screws supplied.
The ventilation unit can be controlled from the cooker
hood control panel.
The electric and control cables as well as the connection
for the cooker hood’s extract air are located under the
cover plates in the bottom of the unit.
99 mm
The fan’s
mounting screws
The kitchen airflow from the
cooker hood during operation in
the boosted flow mode
Condensation/sound
insulation
The kitchen’s general
ventilation via extract air
register
∅
125 mm
2.1.4 Installation of the cooker hood separately
from the ventilation unit
All compatible Swegon CASA cooker hoods can be
mounted separately from the ventilation unit, the
extract air is then led from the cooker hood via a duct to
an extra duct connection on the top of the ventilation
unit. The duct between the cooker hood and the
ventilation unit must be installed in such a way that
makes it possible to clean it.
The ventilation unit can be controlled from the cooker
hood control panel.
∅
100 mm
∅
125 mm
∅
125 mm
The kitchen’s general
ventilation via extract
air register
The kitchen airflow from
the cooker hood during
operation in the boosted
flow mode
Condensation/sound
insulation
Important
The 100 mm duct outlet on the kitchen
bypass should be fitted with a taper piece
for transition to 125 mm as near to the unit
as possible.
!
!