User Manual: Sweetlight FR-252 MK2
12
Switch on condition
The unit always returns to the last mode before it was switched off. In DMX Slave “SLA”
/”SLI”or DMX Mode “d”/”dI” all DMX values are cleared if power is switched off.
DMX signal drop condition
The device will retain the status that it was in before the DMX signal got lost, but
potential tact settings will be automatically cleared.
■ Maintenance
This unit does not need regular maintenance. The internal circuit is protected by a
250V/2A slow-blow fuse 5x20mm fuse. If this fuse fails, this usually indicates an
internal fault requiring servicing by a qualified engineer. The fuse shall only be replaced
by a fuse of same specification, and the replacement has to be made by qualified
personnel obeying applicable safety rules.
■
Technical data Sweetlight FR-252 MK2:
LEDs…..……...……252 pcs. 10mm LEDs (63 red – 108 green – 81 blue) in 3 segments
Dispersion angle………………………………………………………….………...30 degrees
Mains Input……………………………………………………………. AC90-250V~ 50/60Hz
Power supply type………………………………………………………….……..switch mode
Power Consumption…………………….…………………………………………...max. 20W
Fuse………………………………………………….250V 2A T (slow blow, 5x20mm glass)
DMX connections…………………………………………………3 pin XLR (Male / Female)
Modulation Type…………………….…………….Advanced Bit Angle Modulation (ABAM)
Control protocol.......................................................................................DMX 512 (1990)
Dimensions (without brackets)………………….……….L1064.00 x H64.00 x D66.00 mm
Weight …………………………………………………………………………………….1.93kg
■ Standards
This product complies with the following standards:
EU safety................................................................EN60598-1:2008, EN60598-2-1:1989
EU EMC.......................................EN55015: 2006 + A1:2007, EN61547:1995 + A1:2000
EU Harmonics ...................................................................................EN61000-3-2:2006
EU Flicker ………………………………………………………………….EN61000-3-3:2008
US safety ………….…………..………………………………………………………UL60065
US EMC………………………..…………………………………………………..FCC Part 15
This product meets both the EMC Directive 2004/108/EC and the Low Voltage Directive
2006/95/EC.