Do not
drop heavy objects on hose. A sharp
impact may cause internal damage to hose wire
strands. Applying pressure to a damaged hose
may cause it to rupture.
IMPORTANT:
Do not lift hydraulic equipment by
the hoses or swivel couplers. Use the carrying
handle or other means of safe transport.
CAUTION: Keep hydraulic equipment away from
flames and heat.
Excessive heat will soften
packings and seals, resulting in fluid leaks. Heat
also weakens hose materials and packings. For optimum
performance
do not
expose equipment to temperatures of
65°C [150°F] or higher. Protect hoses and cylinders from
weld spatter.
DANGER: Do not handle pressurized hoses.
Escaping oil under pressure can penetrate the skin,
causing serious injury. If oil is injected under the
skin, see a doctor immediately.
WARNING:
Only use consoles in a coupled
system.
WARNING:
Do not use hoses, fittings, or couplers
with pressure ratings below 10,000 psi [700 bar].
Equipment with inadequate pressure rating can fail
and cause personal injury, property or equipment damage.
CAUTION:
To avoid personal injury, do not use
electric consoles in an explosive atmosphere.
Adhere to all local and national electrical codes.
CAUTION:
To help prevent console failure, check
reservoir fluid prior to console operation. If fluid
level is low, add oil. Always be sure tools are fully
retracted before adding fluid to the reservoir.
CAUTION:
To prevent damage to console electric
motor, check specifications and motor plate data.
CAUTION:
To prevent oil spillage, tighten vent/fill
plug when shipping or storing console.
3.0 SPECIFICATIONS — See table below.
4.0 INSTALLATION
1.
Check oil level in reservoir. Oil level should be 1 inch
below vent/fill plug opening. If necessary, add
hydraulic oil to bring oil level up to 1 inch below the
vent/fill opening.
NOTE:
Use only approved hydraulic oil. Use of any other
oils or fluids may damage console or seals and will
void the warranty on your console.
2.
Vent reservoir by turning vent/fill plug 1 to 2 turns
counter-clockwise from fully closed position
.
3.
Be sure the electrical power source is the correct one
for your console. See specification table for electrical
power source specification.
2
®
Model
MX1E-1
MX1E-2
Electrical Power
Source
Motor Rating
1/2 HP Universal
9 Amps at 10,000 psi [700 bar] (@115 VAC)
4.5 Amps at 10,000 psi [700 bar] (@230 VAC)
Weight with Oil
52.5 lbs [23,9 kg]
Operating Pressure
0 - 10,000 psi [0 - 700 bar]
Flow vs. Pressure
200 in
3
/min at 0 - 700 psi [3,3 l/min at 0 - 50 bar]
18 in
3
/min at 10,000 psi [0,3 l/min at 700 bar]
Max. Temperature of
150°F [65° C]
Oil
Reservoir Capacity
0.75 gal [2,8 l] total
0.50 gal [1,9 l] useable
Noise
85-89 dBA
Extension Cords
1 - 50 ft [0-17 m] = 16 AWG
50 - 100 ft [17-34 m] = 14 AWG
9 Amp/115 V, 1-phase, 50/60 Hz Grounded
4.5 Amp/220 V, 1-phase, 50/60 Hz
Specification Table