Swedstyle Memory T Operating Manual Download Page 8

14       Swedstyle Memory T

6.3   Cleaning

1.   Disconnect the height-adjustable desks power supply from the power source.

2.   Wait 30 seconds for residual voltage to dissipate.

3.   Wipe the surface of the Handset with a dry soft cloth or a soft cloth lightly moistened  

in water. Never immerse the Handset into any liquid.

4.   Wait for the Handset to dry completely.

5.   Reconnect the power supply.

6.4    Replacing a handset

1.   Disconnect the Control Box from the Mains.

2.   Disconnect the Handset from the Control Box.

3.   Remove the Handset from the Table Top.

4.   Mount the new Handset onto the Table Top.

5.   Plug the Handset back into the Control Box.

6.   Reconnect the Control Box to the Mains.

6.5   Troubleshooting

Usually, malfunctions occur when Handsets are pressed while calibrating. If the Handset fails to 
function, you will need to restart the system. To do this:

1.   Unplug the Handset from the Control Box.

2.   Plug the Handset back to the motor Control Box.

3.   After a few seconds the Handset is ready for operation.

A list of common problems and their solutions can be found in the Operating Manual  
of the installed Control Box.

6.6 Disposal

The Memory T is subject to the WEEE Directive 2012/19/EU.

 

 

Dispose of all components separately from household waste.  

 

 

Use designated  collection points or disposal companies  

 

 

authorized for this purpose.

Summary of Contents for Memory T

Page 1: ...Swedstyle Memory T 1 MEMORY T 1 0 MANUAL Document Version 2 0 October 2019 TOUCHfamily Swedstyle Memory T Operating manual ...

Page 2: ...eatures 6 3 2 Dimensions 7 4 Assembly 7 4 1 Required components 9 4 2 Process 9 4 3 Completing assembly 9 5 OPERATION 10 5 1 Adjusting the table top height 11 5 2 Saving a memory position 11 5 3 Adjusting the table to a memory position 11 5 4 Key lock 12 5 5 Locked handset 13 6 ADDITIONAL INFORMATION 13 6 1 Disassembly 13 6 2 Maintenance 13 6 3 Cleaning 14 6 4 Replacing a handset 14 6 5 Troublesho...

Page 3: ...ed use may lead to minor injury serious injury or even death Reasonably foreseeable misuse of the Handset includes but does not extend to Connecting unauthorized parts to the product If you are unsure as to whether a part can be used with a Handset contact Swedstyle for further information 2 4 Liability Swedstyle products comply with all currently applicable health and safety regulations However r...

Page 4: ... assembly all parts must be acclimatised to the ambient conditions Do not lift the Handset by its cable This will cause irreparable damage to the product Perform a product risk assessment so that you can respond to potential residual hazards Assembly instructions must be included in your end user Operating Manual MANUAL ocument Version 2 0 October 2019 1 Strain Relief 2 Drilling Holes 3 Memory Pos...

Page 5: ... the Control Box DRILLING TEMPLATE 1 TOUCHfx 2 2 Mounting Screws supplied by Reseller Tool Screwdriver INFO Thread diameter max 5 mm Head diameter 8 5 mm 10 6 mm If possible do not use countersunk head screws 6 2 2 PROC ESS 1 Position the Handset under the table top and mark the position of the drilling holes If necessary use the Drilling Template in chapter 5 3 1 to help you 2 Insert the Stra in ...

Page 6: ...Before using the Table System you must also read the Operating Manual for the installed Control Box including all relevant safety information in full Handset Keys are represented as follows for further description UP Key DOWN Key SAVE Key Memor y Position Key 1 Memory Position Key 2 Memory Position Key 3 Mem ory Position Key 4 SAVE 1 2 3 4 TOUCH FAMILY OPERATING MANUAL PAGE 23 7 1 ADJUSTING THE TA...

Page 7: ...by Swedstyle Only allow Skilled Persons to perform repairs or install accessory parts Contact customer services immediately if the system malfunctions The use of unauthorized spare or accessory parts may cause system damage Warranty claims are void in this scenario Wait until the system has completely stopped before attempting to use the table CAUTION Risk of minor or moderate injury through unsec...

Page 8: ...set onto the Table Top 5 Plug the Handset back into the Control Box 6 Reconnect the Control Box to the Mains 6 5 Troubleshooting Usually malfunctions occur when Handsets are pressed while calibrating If the Handset fails to function you will need to restart the system To do this 1 Unplug the Handset from the Control Box 2 Plug the Handset back to the motor Control Box 3 After a few seconds the Han...

Page 9: ...Swedstyle AB Box 171 SE 567 24 Vaggeryd Sweden info swedstyle se 46 393 363 60 www swedstyle com Smart office solutions ...