Swann Smith's Aegean-EC Series Installation, Commissioning And User Manual Download Page 2

2  |  SmithsEP.co.uk  |  Issue 006 - November 2022

Issue 006 - November 2022 |  SmithsEP.co.uk  |  3

Declaration of conformity

EC Declaration of conformity
We, Smith’s Environmental Products Limited  
1-2 Blackall Industrial Estate 
South Woodham Ferrers 
Chelmsford 
Essex CM3 5UW 
Tel: 01245 324900 Fax: 01245 324422

Declare under sole responsibility that the products:

Product name:  

Aegean

Product range:  

SFC260, SFC235, SVFC500 (model sizes 10, 20, 
25, 30, 40, 50, 55 & 60)

Conform to the following European  
Union directives 

Low Voltage Directive 2014/35/EU Harmonised 
European Standard and Safety Directives

EN 60335-2-80:2003, +A1:04 + A209 
EN 60335-1:2012/AC:14 + A13:2017

Electromagnetic compatibility (EMC) test 
standards 
EN 55014-1:2006 inc A1:2009 & A2 :2011 
EN 61000-3-:2014 
EN 61000-3-3:2013

Immunity  
EN 55014-2:2015 in accordance with category 
2 requirements

This Declaration is made on behalf of Smith’s 
Environmental Products Limited.

Introduction

Smiths Aegean Fan Coil Unit (FCU) is designed 
for heating, cooling and/or ventilating rooms. 
The inlets and outlets of the unit are positioned 
in such a way that the discharged airflow is 
distributed evenly across the room without 
causing discomfort to the people in it. The unit’s 
dimensions are geared to integrating the unit in 
suspended ceilings. 

The fan coil unit blows a flow of air into the room. 
The air may be taken in, at the user’s option, 
either from outside (ventilation) or from the room 
itself (recirculation). Thus, the unit offers two 
benefits: 

•  The room is kept at the desired temperature
•  Gradual deterioration of air quality in the room  
  is counteracted 

Delivery

•  Check the unit and its packaging for correct 
  delivery. Report any transport damage to the 
  driver and supplier immediately
•  Make sure that all parts and components have 
  been supplied 
•  Report any defects to the supplier immediately

Handling

Please ensure that the current Manual Handling 
Regulations are followed.

The infiltration of coarse dust, cement, etc. may 
damage the unit. So long as such contaminants 
are in the room,

•  do not put the unit into operation
•  cover the inlets and outlets

Contents

Introduction 2 
Declaration of conformity 

Symbols used in this guide 

3

Important safety and installation instructions 

4

Product Information 

6

Installation 9
Commissioning 11
Maintenance 12
Fault finding 

14

User manual
Speed controls 

14

Registering your product 

15 

Disposal 15
After sales and spares 

15

Symbols

This manual contains information and 
prescriptions marked by the following symbols.

Ignoring these safety provisions 
marked by the symbol “caution: 
hazard” may endanger the safety 
of people.

Ignoring these safety provisions 
marked by the symbol “caution: 
electricity” may endanger the 
safety of people, as well as the 
integrity of things.

The removal of the screws can 
cause the output of hot fluids 
under high pressure from heating 
system. Drain the system or close 
the isolating valves.

High temperature surface. Take 
utmost care to prevent people 
from getting in contact with the 
hot surfaces of the appliance.

Summary of Contents for Smith's Aegean-EC Series

Page 1: ...Issue 006 November 2022 ENGLISH UK IRL SmithsEP co uk Aegean EC models Installation commissioning and user manual SFC 235 SFC 260 SVFC 500...

Page 2: ...rom the room itself recirculation Thus the unit offers two benefits The room is kept at the desired temperature Gradual deterioration of air quality in the room is counteracted Delivery Check the unit...

Page 3: ...ere dust vapour or gas EN60335 2 51 For other than intended use 6 Installation The appliance must be mounted in a stable fixed position in a dry well ventilated frost free waterproof and protected pla...

Page 4: ...30 A 2 3 235 40 A 2 4 235 50 A 2 3 235 55 A 2 3 235 60 A 2 3 5 Return Cooling Heating Flow Drip Tray 15mm Condensate drain Airflow direction Performance data verification Heating and cooling performa...

Page 5: ...ooling in proper discharge of condensate Position the unit such that the modules will be easy to access both during and after installation Installation 2 Ease of access Adequate access to and around t...

Page 6: ...e pipework must incorporate a sufficient number of hanging support pipe brackets to ensure the pipework does not bow under its own weight Condensate pipework may require lagged insulation depending on...

Page 7: ...surface or use an air duster Wipe out condensate tray and clean with mild detergent if required Vacuum fan and motor assemblies as required or use an air duster Visually inspect for any damaged or fa...

Page 8: ...gives you the peace of mind that in the unlikely event of product failure we will repair or replace the product completely free of charge providing the product has been installed used and maintained i...

Page 9: ...are available nationally from Builders Merchants Plumbers Merchants Heating Equipment Distributors and Kitchen Equipment Distributors In the event of difficulty please contact us or visit our website...