Swagelok FDH1 Application Manual Download Page 8

A Swagelok Pre-Engineered Subsystem        Fluid Distribution Header

8

Dimensions

Dimensions, in inches (millimeters), are for reference only and are subject to change.

FDH Body—A Dimension and Weight

FDH1 inside diameter: 0.79 in. (20.1 mm); FDH2 inside diameter: 1.85 in. (47.0 mm).  
Weights include end caps.

Outlet 

Branch  

Side

 Number of 
Outlets Per 

Side

FDH1 (1 in. 

Pipe Platform)

FDH2 (2 in. 

Pipe Platform)

FDH1 (1 in. 

Pipe Platform)

FDH2 (2 in. 

Pipe Platform)

A, in. (mm)

Weight, lb (kg)

Valves on  

one side

4

 16.5 (419)

 19.8 (503)

  6.9 (3.13)

 16.7  (7.58)

6

 25.5 (648)

 30.2 (767)

 10.3  (4.67)

  24.3 (11.0)

8

 34.5 (876)

  40.8 (1036)

 13.8  (6.26)

  31.9 (14.5)

Valves on  
two sides

2

  7.50 (190)

  9.25 (235)

  3.4 (1.54)

  9.1 (4.13)

3

 12.0 (305)

 14.5 (368)

  5.2 (2.36)

 12.9  (5.85)

4

 16.5 (419)

 19.8 (503)

  6.9 (3.13)

 16.7  (7.58)

5

 21.0 (533)

 25.0 (635)

  8.6 (3.90)

 20.5  (9.30)

6

 25.5 (648)

 30.2 (767)

 10.3  (4.67)

  24.3 (11.0)

7

 30.0 (762)

 35.5 (902)

 12.1  (5.49)

  28.1 (12.7)

8

 34.5 (876)

  40.8 (1036)

 13.8  (6.26)

  31.9 (14.5)

R

R

R

R

B

D

A

C

FDH1 

1.50 (38.1)

FDH2 

2.00 (50.8)

FDH1 

0.80 (20.3)

FDH2 

1.36 (34.5)

FDH1 

1.50 (38.1)

FDH2 

2.00 (50.8)

FDH1 

4.50 (114)

FDH2 

5.25 (133)

Inlet

Drain

Left

Middle

Right

Outlets

(see page 10)

(see page 9)

(see page 11)

Optional 

gauge port

Shown with outlet branch one side right.

Summary of Contents for FDH1

Page 1: ...eks not months Field tested design ensures optimum system performance Versatile manifold for gas and liquid applications Swagelok components for reliability Fluid distribution headers can be connected...

Page 2: ...s Easy to install and operate these subsystems offer the high quality and support you expect from Swagelok Contents Why Use a Fluid Distribution Header 3 Using the Fluid Distribution Header as a Distr...

Page 3: ...an FDH connects several users to the source of a utility fluid Typical applications include Cooling water Steam Compressed air Plant nitrogen In a typical analyzer house for instance one FDH is an in...

Page 4: ...t as a distribution manifold or collection manifold in gas or liquid applications The Swagelok FDH offers several distinctive features Available in 1 and 2 in sizes an extruded manifold body design fe...

Page 5: ...stem Valve selection A variety of Swagelok valves are available to meet temperature and pressure requirements of specific applications See page 7 for pressure temperature ratings Swagelok 40G series i...

Page 6: ...es ball valves See Swagelok One Piece Instrumentation Ball Valves 40G Series and 40 Series catalog MS 02 331 Swagelok 1 and 18 series needle valves See Swagelok Integral Bonnet Needle Valves O 1 18 20...

Page 7: ...s 60 Series Temperature F C Working Pressure psig bar 10 23 to 50 10 1000 68 9 1000 68 9 50 10 1000 68 9 1000 68 9 1000 68 9 100 37 1000 68 9 1000 68 9 1000 68 9 150 65 930 64 0 930 64 0 930 64 0 200...

Page 8: ...419 19 8 503 6 9 3 13 16 7 7 58 6 25 5 648 30 2 767 10 3 4 67 24 3 11 0 8 34 5 876 40 8 1036 13 8 6 26 31 9 14 5 Valves on two sides 2 7 50 190 9 25 235 3 4 1 54 9 1 4 13 3 12 0 305 14 5 368 5 2 2 36...

Page 9: ...8 in 1 20 30 5 1 2 in 1 46 37 1 3 4 in 1 59 40 4 1 in 1 93 49 0 ASME class 150 flange 1 2 in 2 74 69 6 6 36 162 1 in 3 56 90 4 8 14 207 FDH2 2 in Pipe Platform Inlet B Dimension End Connections Inlet...

Page 10: ...110 4 40 112 12 mm 2 24 56 9 5 90 150 4 66 118 4 82 122 Swagelok tube adapter 1 4 in 1 99 50 5 3 8 in 2 06 52 3 1 2 in 2 28 57 9 FDH2 2 in Pipe Platform Outlet D Dimension End Connections Outlet Valv...

Page 11: ...93 2 3 57 90 7 3 8 in 1 25 31 8 3 88 98 6 4 00 102 3 41 86 6 3 49 88 6 1 2 in 1 37 34 8 4 88 124 5 00 127 3 76 95 5 3 84 97 5 3 4 in 1 40 35 6 1 in 1 67 42 4 Metric Swagelok tube fitting 6 mm 2 01 51...

Page 12: ...126 4 85 123 3 4 in 0 88 22 4 5 52 140 1 in 0 88 22 4 5 86 149 Fractional Swagelok tube fitting 3 8 in 2 17 55 1 4 13 105 4 25 108 3 66 90 3 3 74 95 0 1 2 in 1 62 41 1 5 13 130 5 25 133 4 01 102 4 09...

Page 13: ...to 3625 psig 5 Outlet Connections A 1 4 in female NPT B 3 8 in female NPT C 1 2 in female NPT F 1 4 in Swagelok tube fitting G 3 8 in Swagelok tube fitting H 1 2 in Swagelok tube fitting M 6 mm Swagel...

Page 14: ...elok tube adapter Z 1 in Swagelok tube adapter AA 2 in Swagelok tube adapter Available with no inlet valve and 60 series valve only Available with no inlet valve only 5 Outlet Connections B 3 8 in fem...

Page 15: ...blies may include Customized port spacing Other Swagelok products Different manifold lengths Regulatory Compliance Europe Pressure Equipment Directive PED 2014 68 EU Atmospheres Explosive Directive AT...

Page 16: ...proper installation operation and maintenance are the responsibilities of the system designer and user WARNING Do not mix interchange Swagelok products or components not governed by industrial design...

Reviews: