Ordering Information
Build an FDH subsystem ordering number by combining the designators in the sequence shown below.
FDH1 (1 in. Pipe Platform)
FDH1 -
A C
-
C 1 -
C 1 - C 3 - 0
2
4
1
3
5
6
7
8
9
1
Outlet Branch Sides
A
= 1 side right
B
= 1 side left
C
= 2 sides 180° apart
D
= 2 sides right/middle 90° apart
E
= 2 sides left/middle 90° apart
2
Number of Outlets
A
= 4
B
= 6
C
= 8
D
= 10 (2-side configurations
only)
E
= 12 (2-side configurations
only)
F
= 14 (2-side configurations
only)
G
= 16 (2-side configurations
only)
3
Inlet Connections
B
= 3/8 in. female NPT
C
= 1/2 in. female NPT
D
= 3/4 in. female NPT
➀
H
= 1/2 in. Swagelok tube fitting
J
= 3/4 in. Swagelok tube fitting
K
= 1 in. Swagelok tube fitting
➀
P
= 12 mm Swagelok tube fitting
Q
= 25 mm Swagelok tube fitting
➀
S
= 1/2 in. NPS ASME class 150
flange
➀
T
= 1 in. NPS ASME class 150
flange
➀
W
= 3/8 in. Swagelok tube adapter
➁
X
= 1/2 in. Swagelok tube adapter
➁
Y
= 3/4 in. Swagelok tube adapter
➁
Z
= 1 in. Swagelok tube adapter
➁
➀
Available with no inlet valve and 60 series valve
only
.
➁
Available with no inlet valve
only.
8
Drain Valve
0
= None
1
= 40G (1/4 in. and 6 mm drain
connections) or 40 series (all other
drain connection sizes) ball valve
2
= 60 series ball valve
3
= 1 or 18 series needle valve
4
= P4T or P6T series plug valve
9
Pressure Gauge
Gauges are dual scale with bar primary
and psig secondary scales.
0
= None
1
= 0 to 10 bar (0 to 145 psig)
2
= 0 to 40 bar (0 to 580 psig)
3
= 0 to 100 bar (0 to 1450 psig)
4
= 0 to 160 bar (0 to 2320 psig)
5
= 0 to 250 bar (0 to 3625 psig)
5
Outlet Connections
A
= 1/4 in. female NPT
B
= 3/8 in. female NPT
➀
C
= 1/2 in. female NPT
➂
F
= 1/4 in. Swagelok tube fitting
G
= 3/8 in. Swagelok tube fitting
H
= 1/2 in. Swagelok tube fitting
➂
M
= 6 mm Swagelok tube fitting
N
= 10 mm Swagelok tube fitting
P
= 12 mm Swagelok tube fitting
➂
V
= 1/4 in. Swagelok tube adapter
➁
W
= 3/8 in. Swagelok tube adapter
➁
X
= 1/2 in. Swagelok tube adapter
➁
➀
Available with no outlet valve, 40G or 40 series
valve, 1 or 18 series valve, and 60 series valve
only.
➁
Available with no outlet valve
only.
➁
Not available with 40 series valves
4
Inlet Valve
0
= None
1
= 40G (1/4 in. and 6 mm inlet
connections) or 40 series (all other
inlet connection sizes) ball valve
2
= 60 series ball valve
6
Outlet Valve
0
= None
1
= 40G (1/4 in. and 6 mm outlet
connections) or 40 series (all other
outlet connection sizes) ball valve
2
= 60 series ball valve
3
= 1 or 18 series needle valve
4
= P4T or P6T series plug valve
7
Drain Connection
A
= 1/4 in. female NPT
B
= 3/8 in. female NPT
➀
C
= 1/2 in. female NPT
D
= 3/4 in. female NPT
➁
F
= 1/4 in. Swagelok tube fitting
G
= 3/8 in. Swagelok tube fitting
H
= 1/2 in. Swagelok tube fitting
J
= 3/4 in. Swagelok tube fitting
➂
K
= 1 in. Swagelok tube fitting
➂
M
= 6 mm Swagelok tube fitting
N
= 10 mm Swagelok tube fitting
P
= 12 mm Swagelok tube fitting
Q
= 25 mm Swagelok tube fitting
➂
S
= 1/2 in. NPS ASME class 150
flange
➁
T
= 1 in. NPS ASME class 150
flange
➁
V
= 1/4 in. Swagelok tube adapter
➂
W
= 3/8 in. Swagelok tube adapter
➂
X
= 1/2 in. Swagelok tube adapter
➂
Y
= 3/4 in. Swagelok tube adapter
➂
Z
= 1 in. Swagelok tube adapter
➂
ZZ
= Plug
➀
Available with no drain valve, 40G or 40 series
valve, 1 or 18 series valve, and 60 series valve
only.
➁
Available with no drain valve and 60 series valve
only.
➂
Available with no drain valve
only.