Swagelok FDH1 Application Manual Download Page 1

 A Swagelok

®

 Pre-Engineered 

Subsystem

•  Pre-engineered subsystems 

available in weeks, not months.

•  Field-tested design ensures 

optimum system performance.

•  Versatile manifold for gas and liquid applications

•  Swagelok components for reliability

•  Fluid distribution headers can be connected inline to 

create longer lengths

Fluid 

Distribution 

Header

Application Guide

Summary of Contents for FDH1

Page 1: ...eks not months Field tested design ensures optimum system performance Versatile manifold for gas and liquid applications Swagelok components for reliability Fluid distribution headers can be connected...

Page 2: ...s Easy to install and operate these subsystems offer the high quality and support you expect from Swagelok Contents Why Use a Fluid Distribution Header 3 Using the Fluid Distribution Header as a Distr...

Page 3: ...an FDH connects several users to the source of a utility fluid Typical applications include Cooling water Steam Compressed air Plant nitrogen In a typical analyzer house for instance one FDH is an in...

Page 4: ...t as a distribution manifold or collection manifold in gas or liquid applications The Swagelok FDH offers several distinctive features Available in 1 and 2 in sizes an extruded manifold body design fe...

Page 5: ...stem Valve selection A variety of Swagelok valves are available to meet temperature and pressure requirements of specific applications See page 7 for pressure temperature ratings Swagelok 40G series i...

Page 6: ...es ball valves See Swagelok One Piece Instrumentation Ball Valves 40G Series and 40 Series catalog MS 02 331 Swagelok 1 and 18 series needle valves See Swagelok Integral Bonnet Needle Valves O 1 18 20...

Page 7: ...s 60 Series Temperature F C Working Pressure psig bar 10 23 to 50 10 1000 68 9 1000 68 9 50 10 1000 68 9 1000 68 9 1000 68 9 100 37 1000 68 9 1000 68 9 1000 68 9 150 65 930 64 0 930 64 0 930 64 0 200...

Page 8: ...419 19 8 503 6 9 3 13 16 7 7 58 6 25 5 648 30 2 767 10 3 4 67 24 3 11 0 8 34 5 876 40 8 1036 13 8 6 26 31 9 14 5 Valves on two sides 2 7 50 190 9 25 235 3 4 1 54 9 1 4 13 3 12 0 305 14 5 368 5 2 2 36...

Page 9: ...8 in 1 20 30 5 1 2 in 1 46 37 1 3 4 in 1 59 40 4 1 in 1 93 49 0 ASME class 150 flange 1 2 in 2 74 69 6 6 36 162 1 in 3 56 90 4 8 14 207 FDH2 2 in Pipe Platform Inlet B Dimension End Connections Inlet...

Page 10: ...110 4 40 112 12 mm 2 24 56 9 5 90 150 4 66 118 4 82 122 Swagelok tube adapter 1 4 in 1 99 50 5 3 8 in 2 06 52 3 1 2 in 2 28 57 9 FDH2 2 in Pipe Platform Outlet D Dimension End Connections Outlet Valv...

Page 11: ...93 2 3 57 90 7 3 8 in 1 25 31 8 3 88 98 6 4 00 102 3 41 86 6 3 49 88 6 1 2 in 1 37 34 8 4 88 124 5 00 127 3 76 95 5 3 84 97 5 3 4 in 1 40 35 6 1 in 1 67 42 4 Metric Swagelok tube fitting 6 mm 2 01 51...

Page 12: ...126 4 85 123 3 4 in 0 88 22 4 5 52 140 1 in 0 88 22 4 5 86 149 Fractional Swagelok tube fitting 3 8 in 2 17 55 1 4 13 105 4 25 108 3 66 90 3 3 74 95 0 1 2 in 1 62 41 1 5 13 130 5 25 133 4 01 102 4 09...

Page 13: ...to 3625 psig 5 Outlet Connections A 1 4 in female NPT B 3 8 in female NPT C 1 2 in female NPT F 1 4 in Swagelok tube fitting G 3 8 in Swagelok tube fitting H 1 2 in Swagelok tube fitting M 6 mm Swagel...

Page 14: ...elok tube adapter Z 1 in Swagelok tube adapter AA 2 in Swagelok tube adapter Available with no inlet valve and 60 series valve only Available with no inlet valve only 5 Outlet Connections B 3 8 in fem...

Page 15: ...blies may include Customized port spacing Other Swagelok products Different manifold lengths Regulatory Compliance Europe Pressure Equipment Directive PED 2014 68 EU Atmospheres Explosive Directive AT...

Page 16: ...proper installation operation and maintenance are the responsibilities of the system designer and user WARNING Do not mix interchange Swagelok products or components not governed by industrial design...

Reviews: