Troubleshooting

Symptom

Cause

Remedy

Tubing is difficult to remove from the 

MHSU.

There has been normal tube 

expansion.

Rock the tubing gently back and forth.

       

CAUTION

        Do not rotate the tubing, or  

        system leakage may result.

Tube wall thickness may be below the 

recommended level.

Refer to the tubing listed in the 

Medium- and High-Pressure Fittings, 

Tubing, Valves, and Accessories

 

catalog, MS-02-472, for FK fittings.

The indicator knob fails to release.

Oil may need to be added.

Place the unit on a horizontal surface. 

Check the oil level, and fill to the 

lowest thread if necessary. Use 10W, 

AW-46 grade hydraulic oil or equivalent 

with an antifoaming additive.

If the oil reservoir is full and symptom 

persists, return the unit to your 

authorized Swagelok representative.

The die head piston does not return 

fully after swaging.

The die head piston may be damaged.

Return the unit to your authorized 

Swagelok representative.

The pump is failing to build pressure.

The oil level is incorrect. 

Too much or too little oil prevents the 

pump from working properly.

Add or remove oil as necessary with 

the unit on a horizontal surface. Use 

10W, AW-46 grade hydraulic oil or 

equivalent with an antifoaming additive.

There is oil around the pump.

There has been normal wear to the 

pump components.

A small amount of leakage is 

acceptable. If oil is continuously 

dripping or there is a puddle, return 

the unit to your authorized Swagelok 

representative.

Proper Oil Level