SpeciIfications
Accuracy is specified for a period of one year after calibration and at 18 to 28°C (64°F to 82°F)
with relative humidity to 80%.
General
Maximum voltage between terminals and earth ground: CAT II 500V
Fuse protection: FH 500mA/500V 10A/500V
Power: 9V battery, NEDA 1604 or 6F22
Display: LCD, 1999 counts, updates 2-3/ sec.
Measuring method: Dual-slope integration A/D converter
Overrange Indication: Only figure “1” on the display
Polarity indication: “-”displayed for negative polarity
Operating Environment : 0 to 40 °C
Storage temperature: -10 °C to 50 °C.
Low battery indication: “ ”appears on the display
Size: 138mm x 69mm x 31mm
Weight: Approx.160g
Operating Instructions
DC Voltage Measurement
1. Connect the red test lead to the “V.Ω.mA” jack and the black lead to the “COM” jack.
2. Set rotary switch at desired DCV position. If the voltage to be measured is not known beforehand, set
range switch at the highest range position and then reduce it until satisfactory resolution is obtained.
3. Connect test leads across the source or load being measured.
4. Read voltage value on the LCD display along with the polarity of the red lead connection.