-7-

5.3. 

SVT-4 

WIRING CONNECTION

1. Red

2. Blue

3. Yellow

4. White

      4-Video

1-Audio   

 2-GND   

  3-V+

5.3.1 

Indoor Monitor

1. Red
2. Blue
3. Yellow
4. White

1. Red
2. Blue
3. Yellow
4. White

NOTE:

 Do not remove  any of the  jumpers from the back of the indoor 

monitors. 

By removing a jumper or changing its position, some of the features may 

not work properly.

5.3.2 

Outdoor Station

Upper module:

CN1

Use this port to connect indoor monitors.

J1:

 Must remain connected to J1 port on the lower module.

Lower module:

J1:

 Must remain connected to J1 port on the upper module.

J3:

 Use this port to connect a door lock.

      The door lock is limited to 14.5V, 120mA.

       Must use an additional power supply for the door lock. Ensure the power supply is 

compatible with the door lock specifications.

J4:

 Exit button connection port.

Summary of Contents for SVT-4 Outdoor Station C

Page 1: ...SVT 4 Outdoor Station C User Manual Please read this user manual prior to installing the system and keep it well for future use ...

Page 2: ...m with two entrances 6 6 Cable Requirements 10 7 User Instructions 11 5 3 SVT 4 Wiring Connection 7 7 1 Visitor calls 11 7 2 Monitor 12 7 3 Intercom 13 4 1 Mounting without the Rain Guard 3 4 2 Mounting with the Rain Guard 4 4 3 Mounting the Indoor Monitor 4 5 3 1 Indoor Station 7 5 3 2 Outdoor Station 7 8 8 How to set up User Codes 14 15 5 3 3 Electric door lock connection 9 ...

Page 3: ... 5 Call button Built in microphone Description 1 Built in microphone 2 Monitor button 3 Intercom button 4 Door unlock button 5 Talk button 6 TFT 7 color display 7 Built in speaker 8 Talking Ring volume 9 Brightness 10 Contrast Status light Calling in red light Monitoring Talking blue light 6 Keypad ...

Page 4: ... 2 2 Terminal Descriptions ...

Page 5: ...r Supply Must be used according to lock Unlocking time 01 99 seconds Communication duration 120s Communication transmission 2 way communication Working temperature 4 F to 131 F 20 C to 55 C INDOOR MONITOR Voltage DC 14 5V Communication duration 120s Communication transmission 2 way communication Working temperature 14 F to 131 F 10 C to 55 C 4 1 MOUNTING WITHOUT THE RAIN GUARD ...

Page 6: ... 4 Screw anchors Screws Screws fix with rain cover Rain cover Wall hole 4 2 MOUNTING WITH THE RAIN GUARD 4 3 MOUNTING THE INDOOR MONITOR ...

Page 7: ... 5 5 1 SVT 4 SYSTEM WITH ONE ENTRANCE System Wiring and Connections 5 Outdoor station 1 Power supply for lock ...

Page 8: ... 6 5 2 SVT 4 SYSTEM WITH TWO ENTRANCES Outdoor station 1 Outdoor station 2 Power supply for lock Power supply for lock ...

Page 9: ...on some of the features may not work properly 5 3 2 Outdoor Station Upper module CN1 Use this port to connect indoor monitors J1 Must remain connected to J1 port on the lower module Lower module J1 Must remain connected to J1 port on the upper module J3 Use this port to connect a door lock The door lock is limited to 14 5V 120mA Must use an additional power supply for the door lock Ensure the powe...

Page 10: ... 8 NC COM NO Door Lock To Indoor Monitor Adjust Talking Volume Exit Button Adjust Camera Position ...

Page 11: ...tion 1 Use the port J3 of the lower module to connect a door lock 2 The door lock is limited to 14 5V 120mA 3 Must use an additional power supply for the door lock Ensure the power supply is compatible with the door lock specifications ...

Page 12: ...s may affect the maximum distance the system can reach 230 feet 70 meters 30 feet 10 meters NOTE 1 The system expands to a maximum of 2 outdoor stations and 4 indoor monitors 2 Each indoor monitor requires its own power supply 14 5V 1 3A 3 We recommend soldering the wires together to ensure a good connection Do not use wire nuts 10 ...

Page 13: ... shown on the monitor 7 1 Visitor calls Check After pressing the unlocked button the indoor monitor still displays the image from the front door camera End the call Talk begins Open the lock The talk time is up to 2 minutes Press the TALK button or hang up the handset The visitor presses the call button on outdoor station 1 Ring Ring The visitor presses the call button on outdoor station 2 7 User ...

Page 14: ...ain indoor monitor to extension indoor monitor Any indoor monitor press button or pick up the handset to talk with the outdoor station Press twice Press once The indicator light of Door 1 is on The indicator light of Door 2 is on End the monitor Press the monitor button Monitor outdoor station 1 Monitor outdoor station 2 Press the talk button Press the talk button Monitor the outdoor station Press...

Page 15: ...button or hang upbutton or hang up the handsetthe handset Talk begins Any indoor monitor presses button or pickup the handsetto talk 7 3 Intercom In the standby mode press intercom button in any indoor monitor During the talking any indoor monitor presses the intercom button ...

Page 16: ...g mode 1 Press DI sound should be heard twice and then enter 4 digit programming password DI sound should be heard three times with LED light flashing It indicates entering to the programming mode successfully 2 Press to exit the programming mode with DI sound in five times Set unlocked time Factory default setting is 5 seconds 1 Enter to the programming mode first 2 Enter code 00 and DI sound sho...

Page 17: ...s it indicates password stored succeeds Return to the programming mode 1 Enter to the programming mode first 2 Press After DI sound is heard twice press again Anther DI sound is heard twice 3 Then press for seven times the system deletes all the setting The unlocked time changes to 1 second and the programming password does not change After hearing DI sound for five times the system reset and all ...

Page 18: ......

Page 19: ......

Page 20: ...The design and specifications of this user manual can be changed without any notification to the user All copyright and interpretation rights are reserved to SVT Innovations Inc ...

Reviews: