background image

4

Description

The Receiver Module SHR-7 receives and demodulates the transmitter signal and forwards it to the evaluation circuit (not included in 
this module). The receiver add-on board layout allows adapting to a maximum range of different uses and applications.

To avoid that unwanted signals with different frequencies are evaluated, an input frequency filter circuit is used, which also contributes 
to a high input sensitivity. This guarantees a disturbance free operation as much as possible.

The Receiver Module can be used within the EU and Switzerland without additional registration permits or fees.

5

Operation

For the location of the receiver module, select a place which is not
shielded by conducting objects and position the antenna in such a way
that it is not subject to interference from the rest of the circuit and is
parallel to the transmitter antenna. 

Power Supply: Connect the voltage supply  (7…14 V) between the
pins GND (0 V) and +U (pay attention to the c/- connection)!

If the voltage supply exceeds the specified voltage, the
electronic components may be destroyed. Since the
circuit is unprotected, it is necessary to avoid static

discharges and mechanic influences

.

Data Output: Transistor output with 15 kOhm pull-up resistor with +5V internally controlled. The data sequence received from the 
transmitter at the receiver output is inverted. This needs to be taken into account when processing the data. 

Clocked Operation: When shipped, the receiver module is set to continuous operation and requires app. 6.5 mA. For applications that 
require less current supply, the module can be operated in a clocked modus. For this, the user just needs to remove the resistor  
“clocked operation” shown in the Figure. The mean current supply is then .25 mA. The user should be aware that the transmitter has to 
be sending for at least 1.3 seconds for the receiver to safely detect the transmitter signal and the data be evaluated.

Antenna: The receiver module is shipped without an antenna (see Chap. 6).

Antenna Connection

A wire of app. 17,3 cm length can be used as an antenna if soldered
directly at the output  „ANT“. However, the best receiving
characteristics can be achieved with the Multiflex Antenna, Id.-Nr.
00069.00. If the antenna needs to be installed at a different location,
the user can use an extension with a 50-Ohm coaxial cable (see fig.)

The antenna should be positioned vertically to the board
or to any other device and should not be screened by
conducting objects and should be parallel to the 

transmitter antenna.

7

Technical Data

Frequency:

433,920 MHz

LF-Bandwidth:

ca. 20 Hz to 2 kHz

Demodulation:

ASK

Evaluation sensitivity:

tip. < -105 dBm

Operating Voltage:

7 to 14 V DC

Current: 6,5 mA (clocked app. 0,25 mA)

Ambient temperature:

-20 °C to +65 °C

Storage temperature:

-40 °C to +85 °C

Dimensions :

45,2 (32,6) x 23,1 x 7 mm

Connectors:

Pin panel with separation of 2,54mm

4

 -

ANT

GND-ANT

Antenna

grounded plane

< 10 m

Summary of Contents for SHR-7

Page 1: ...ften des Verbandes der gewerblichen Berufsgenossenschaft f r elektrische Anlagen und Betriebsmittel zu beachten In Schulen Ausbildungseinrichtungen Hobby und Selbsthilfewerkst tten ist das Betreiben d...

Page 2: ...sch digt werden Datenausgang Transistorausgang mit 15kOhm Pull Up Widerstand nach intern geregelten 5V Die vom Sendemodul empfangenen Daten werden am Empf nger invertiert ausgegeben Bei der Datenweite...

Page 3: ...rities For use in public institutions schools clubs and do it yourself workshops the operation of this product has to be supervised by qualified personnel We do not assume any warranty and liability f...

Page 4: ...nverted This needs to be taken into account when processing the data Clocked Operation When shipped the receiver module is set to continuous operation and requires app 6 5 mA For applications that req...

Page 5: ...ation les ateliers de bricolage ou d activit s sociales doit toujours tre surveill e sous la responsabilit de personnel qualifi et comp tent L installation ne doit tre effectu e que par du personnel q...

Page 6: ...image 1 La consommation moyenne d nergie se monte 0 25 mA Il faut savoir que l metteur doit mettre au moins pendant 1 3s pour garantir le r veil du r cepteur C est seulement ce moment l que les donn e...

Page 7: ...Equipment Directive RED 2011 65 EU Restriction of Hazardous Substances RoHS und dass die nachstehenden harmonisierten europ ischen Normen zur Anwendung gelangt sind and that the following harmonized...

Reviews: