Chapter 1: VT-70 Modulator
VR-70 and DCM User’s Manual
Page 28
•
ENT: This button has several functions. It is used to enter submenus
1
,
to select an option when there are several choices and for other specific
functions.
6.3 “Monitor Status” Menu
The monitor status menu is used to monitor the status of different
parameters of the VR-70 modulator, the DCM down-converter and UCM up-
converter. It can not be used to configure these parameters.
This section contains a detailed description of all the parameters that can
be monitored or displayed with the MONITOR STATUS menu of the VR-70
demodulator.
To enter this menu, press the MENU button, use the UP and DOWN buttons
to select the MONITOR STATUS menu, and then press the ENT button.
In the first line of the MONITOR STATUS menu the equipment model (VR-
70 in this case), the serial number and the software version are displayed.
The UP and DOWN buttons are used to navigate through the menu options.
The table below shows the different options in the MONITOR STATUS
menu:
Table 6.1 “Monitor Status” menu
Line no.
Function
1
Model, serial no. and software version.
2
The location of the equipment and source and destination
nodes of the link. Press ENT key to enter a submenu that
displays the location of the equipment and the locations of
the source and destination nodes of the communication
link.
3
Reception frequency in MHz.
When the frequency is configured manually, using the
channel selector in the up converter, the VR-70 displays
the channel number and the reception frequency preceded
by blinking MN characters.
If the frequency is configured from the SETUP
CONFIGURATION menu (channel selector set to 0 in the
down-converter), the equipment displays the reception
frequency and the label slave in brackets. Consequently the
down-converter is configured from the VR-70 demodulator.
1
The existence of a submenu is indicated on the display with the ENTER symbol
Summary of Contents for DCM-1070
Page 1: ...SVP Broadcast Microwave VR 70 DCM 1070 User s Manual V 1 1 10GHz Receiver...
Page 3: ...Preliminary pages VR 70 and DCM User s Manual Page 3...
Page 4: ...Preliminary pages VR 70 and DCM User s Manual Page 4...
Page 7: ...Chapter 1 VR 70 Demodulator Repeater...
Page 38: ...Chapter 2 Multi frequency Down Converter DCM 1070 series...
Page 46: ...Chapter 3 Parabolic antenna installation Chapter 3 Parabolic antenna Installation...
Page 51: ...Chapter 3 Parabolic antenna installation Page 51 VT 70 and UCM up converter user s manual...
Page 52: ...Chapter 3 Parabolic antenna installation Page 52 VT 70 and UCM up converter user s manual...
Page 53: ...Chapter 3 Parabolic antenna installation Page 53 VT 70 and UCM up converter user s manual...
Page 54: ...Chapter 3 Parabolic antenna installation Page 54 VT 70 and UCM up converter user s manual...
Page 55: ...Chapter 3 Parabolic antenna installation Page 55 VT 70 and UCM up converter user s manual...
Page 56: ...Chapter 3 Parabolic antenna installation Page 56 VT 70 and UCM up converter user s manual...
Page 57: ...Chapter 3 Parabolic antenna installation Page 57 VT 70 and UCM up converter user s manual...
Page 58: ...Chapter 3 Parabolic antenna installation Page 58 VT 70 and UCM up converter user s manual...
Page 59: ...Chapter 3 Parabolic antenna installation Page 59 VT 70 and UCM up converter user s manual...
Page 60: ...Chapter 3 Parabolic antenna installation Page 60 VT 70 and UCM up converter user s manual...
Page 61: ...Chapter 3 Parabolic antenna installation Page 61 VT 70 and UCM up converter user s manual...
Page 62: ...Chapter 3 Parabolic antenna installation Page 62 VT 70 and UCM up converter user s manual...
Page 63: ...Chapter 4 MD 70 External Signal Meter...