6. TROUBLESHOOTING

Problem

The UPS is connected 

to the mains, but the 

indicator does not 

light.

The UPS beeps and 

operates in the 

o

-line mode even 

with normal voltage in 

the mains.

The UPS operates 

from the mains, but 

does not operate in 

the o

-line mode.

The UPS beeps long 

during operation from 

the mains.
The UPS does not 

provide the expected 

time of operation in 

the o

-line mode or it 

is switched o

.

Cause

1. The switch in not on.
2. Input fuse has come into action.
3. Unreliably connected cables.

1. The UPS found depressions or 
surges in input voltage and has gone 
to the standby mode.
2. Input fuse has come into action. 
3. Poor contact in the UPS connec- 
tion circuits to the mains.

1. Batteries are discharged greatly.
2. Defective batteries.
3. The UPS is to be repaired.

Overload.

1. Batteries are discharged greatly.

2. Defective batteries.
3. Circuit of connecting cables of 

batteries is open.

Solution

1. Switch on the switch.
2. Switch o

 the load. Press the 

fuse button. If the UPS operation 
is normal check the load power.
3. Disconnect cables and connect 
them once again.
1. It is normal phenomenon. The 
UPS protects the equipment 
against voltage disorders of the 
mains.
2. Disconnect the load. Press the 
fuse button. If the UPS operation 
is normal check the load capacity.
3. Check the UPS connection 
reliability to the mains.
1. Disconnect all equipment and 
charge batteries in full.
2. Replace batteries.
3. Consult with the service center. 
Decrease the connected load 
power.

1. Charge batteries in full.
2. Replace batteries.
3. Checkt the connection reliability 
of cables to batteries.

If none of the above methods can solve the problem, please seek professional advice at your 

nearest service center. Never attempt to repair the product yourself.

ENG

7

Operation Manual

Reserve

Home

Summary of Contents for Reserve Home

Page 1: ...www sven fi OPERATION MANUAL Reserve Home Uninterruptible Power Supply...

Page 2: ...e device carefully Make sure there are no accessories left in the box Check up the device for damage if the product was damaged during transportation address the firm which carried out the delivery if...

Page 3: ...ric shock In case of an emergency turn o the UPS and disconnect the power cord from the mains It is strictly prohibited to open the device case there is high voltage inside In case of any problems con...

Page 4: ...providing correct power supply of load at overvoltage undervoltage of the mains without going to the operation mode from batteries The intellectual circuit of battery charging is used in the device wh...

Page 5: ...its value goes beyond its rate g CHECK error indicator h UPS on o button i OVERLOAD overload indicator j buzzer on o button k RS232 RS232 connector l AC Input power cord m Circuit Breaker automatic te...

Page 6: ...on the five segment indicator c every segment displays approx 20 of the battery capacity When the battery is charged completely approx 12 hours all 5 segments of the indicator c must light When the b...

Page 7: ...ns in premises where the device placement is intended must correspond to the norms indicated in the Technical Specifications table The UPS must be stored with batteries full charged Storage conditions...

Page 8: ...teries are discharged greatly 2 Defective batteries 3 Circuit of connecting cables of batteries is open Solution 1 Switch on the switch 2 Switch o the load Press the fuse button If the UPS operation i...

Page 9: ...ode Output waveform Protection Cooling type Beeps Switching time msec Battery plug in external optional Temperature conditions Storage temperature Humidity Noise level dB Dimensions W H D mm Weight kg...

Page 10: ...ve Home 500 800 1000 111024 65 1 105082 75 5 www sven fi 24 5 176 02 02 427447 48310 15 Manufacturer SVEN PTE LTD 176 Joo Chiat Road 02 02 Singapore 427447 Produced under the control of Oy Sven Scandi...

Reviews: