background image

Cold start function 

 The UPS can be switched on without connection to the mains using the cold start function. In 

order to switch on the UPS, press and hold down the button 

h

 within 4 sec. The buzzer beeps four 

times, the output voltage indicator 

a

 displays the 

fi

gure “220” and the power will be supplied to 

devices-consumers. 

Note. It is not recommended to use the cold start function when the connected load is 

large.

Sound alarm and protection

 At the instant the UPS starts to use power from batteries, it beeps 4 times. Then the UPS beeps  

every 30 seconds, when it operates from batteries. This function can be switched o

. To do this, 

press and hold down the button 

j

 within 2 sec., the buzzer beeps one time and signals will be 

over. When beeps are required, repeat the procedure.   

 If the battery capacity is low (while operating from batteries), the UPS beeps every second.

 When the battery residual voltage is lower than 10.5 V, the UPS is switched o

 When load is too high (approx. 110 %), the UPS beeps continuously. When load is 120 % or more 

the UPS is switched o

Storage conditions

 The temperature and humidity conditions in premises, where the device placement is intended, 

must correspond to the norms indicated in the Technical Speci

fi

cations table. 

 The UPS must be stored with batteries full charged.

 Storage conditions of batteries should comply with the manufacturer’s requirements.

Monitoring program

 Monitoring program of the UPS, which can be downloaded on 

www.sven.

fi

 website, allows con- 

trolling its operation condition and registering its operating parameters. It is compatible with most 

operating systems. The UPS is connected to PC with RS232 cable (not included) via RS232 port. 

More detailed information you can see in the Software Manual on 

www.sven.

fi

 website.

The approximate battery/batteries time of operation of uninterruptible power supplies of 

RESERVE HOME series in accordance with the load rate and a battery/batteries capacity. 

Reserve Home-500

Reserve Home-1000

Reserve Home-800

12V/50 

А

·h

12V/75 

А

·h

12V/100 

А

·h

12V/150 

А

·h

12V/200 

А

·h

3.41 h
5.11 h

6.82 h

10.23 h
13.65 h

1.70 h
2.55 h

3.41 h
5.11 h

6.82 h

1.13 h

1.70 h
2.27 h

3.41 h
4.55 

ч

0.85 h
1.28 h

1.71 h

2.56 h

3.41 h

0.71 h
1.06 h
1.42 h
2.13 h

2.84 h

0.68 h
1.02 h
1.36 h
2.05 h
2.73 h 

0.57h

0.85 h

1.14 h
1.71 h

2.28 h

Load

100 W

Load

200 W

Load

300 W

Load

400 W

Load

480 W

Load

500 W

Load

600 W

Battery

capacity

ENG

6

Uninterruptible

Power Supply

Summary of Contents for Reserve Home

Page 1: ...www sven fi OPERATION MANUAL Reserve Home Uninterruptible Power Supply...

Page 2: ...e device carefully Make sure there are no accessories left in the box Check up the device for damage if the product was damaged during transportation address the firm which carried out the delivery if...

Page 3: ...ric shock In case of an emergency turn o the UPS and disconnect the power cord from the mains It is strictly prohibited to open the device case there is high voltage inside In case of any problems con...

Page 4: ...providing correct power supply of load at overvoltage undervoltage of the mains without going to the operation mode from batteries The intellectual circuit of battery charging is used in the device wh...

Page 5: ...its value goes beyond its rate g CHECK error indicator h UPS on o button i OVERLOAD overload indicator j buzzer on o button k RS232 RS232 connector l AC Input power cord m Circuit Breaker automatic te...

Page 6: ...on the five segment indicator c every segment displays approx 20 of the battery capacity When the battery is charged completely approx 12 hours all 5 segments of the indicator c must light When the b...

Page 7: ...ns in premises where the device placement is intended must correspond to the norms indicated in the Technical Specifications table The UPS must be stored with batteries full charged Storage conditions...

Page 8: ...teries are discharged greatly 2 Defective batteries 3 Circuit of connecting cables of batteries is open Solution 1 Switch on the switch 2 Switch o the load Press the fuse button If the UPS operation i...

Page 9: ...ode Output waveform Protection Cooling type Beeps Switching time msec Battery plug in external optional Temperature conditions Storage temperature Humidity Noise level dB Dimensions W H D mm Weight kg...

Page 10: ...ve Home 500 800 1000 111024 65 1 105082 75 5 www sven fi 24 5 176 02 02 427447 48310 15 Manufacturer SVEN PTE LTD 176 Joo Chiat Road 02 02 Singapore 427447 Produced under the control of Oy Sven Scandi...

Reviews: