5. УСЛОВИЯ ЭКСПЛУАТАЦИИ И ХРАНЕНИЯ

Íå ýêñïëóàòèðóéòå ÈÁÏ â ïîìåùåíèÿõ, ãäå òåìïåðàòóðà îêðóæàþùåãî âîçäóõà íå ñîîòâåòñòâóåò ïðèâåäåííîé â ðàçäåëå «Òåõíè-
÷åñêèå õàðàêòåðèñòèêè».

Ýêñïëóàòàöèÿ

1. Êîðïóñ èñòî÷íèêà ïðè ðàáîòå â àâòîíîìíîì ðåæèìå è â ðåæèìå çàðÿäà àêêóìóëÿòîðíûõ áàòàðåé íàãðåâàåòñÿ. Çàêðûâàòü âåí-
òèëÿöèîííûå îòâåðñòèÿ êîðïóñà è ýêñïëóàòèðîâàòü ÈÁÏ â çàìêíóòîì ïðîñòðàíñòâå íå äîïóñêàåòñÿ!
2. Ïîâòîðíîå âêëþ÷åíèå ÈÁÏ ïîñëå îòêëþ÷åíèÿ ðåêîìåíäóåòñÿ ìèíèìóì ÷åðåç 2 ñåêóíäû.
3. Çàïðåùàåòñÿ ïîäêëþ÷åíèå ýëåêòðîíàãðåâàòåëüíûõ ïðèáîðîâ ê ÈÁÏ 

Óñëîâèÿ õðàíåíèÿ

ÈÁÏ äîëæåí õðàíèòüñÿ çàêðûòûì, â âåðòèêàëüíîì ïîëîæåíèè, â ñóõîì ïðîõëàäíîì ìåñòå ñ ïîëíîñòüþ çàðÿæåííûì àêêóìóëÿòî-
ðîì.
Ïåðåä òåì êàê ïîñòàâèòü ÈÁÏ íà õðàíåíèå, çàðÿäèòå åãî â òå÷åíèå 10 ÷àñîâ.
Âî èçáåæàíèå èñòîùåíèÿ àêêóìóëÿòîðà îòêëþ÷èòå êàáåëè, ïîäêëþ÷åííûå ê ïîðòó èíòåðôåéñà êîìïüþòåðà.

Äëèòåëüíîå õðàíåíèå

Ïðè äëèòåëüíîì õðàíåíèè â óñëîâèÿõ òåìïåðàòóðû îêðóæàþùåé ñðåäû îò +15 äî
+30 °Ñ àêêóìóëÿòîð ÈÁÏ ñëåäóåò çàðÿæàòü êàæäûå 6 ìåñÿöåâ.

6. ЭЛЕМЕНТЫ УПРАВЛЕНИЯ И ИНДИКАТОРЫ

6. 1. Âíåøíèé âèä ëèöåâîé ïàíåëè ìîäåëåé Pro+ 500/700

a

Êíîïêà âêëþ÷åíèÿ ÈÁÏ

b

Èíäèêàòîð ðàáîòû îò ñåòè

c

Èíäèêàòîð ðàáîòû îò áàòàðåé (àâòîíîìíûé ðåæèì)

d

Èíäèêàòîð çàðÿäà áàòàðåé

6.2. Âíåøíèé âèä çàäíåé ïàíåëè ìîäåëåé Pro+500/700

a

Ìîäóëü ðàçúåìîâ çàùèòû ìîäåìà/òåëåôîííîé ëèíèè

Êîìáèíèðîâàííûé ìîäóëü ðàçúåìîâ RJ-11/RJ-45 èñïîëüçóåòñÿ äëÿ çàùèòû
ìîäåìà/ôàêñà îò ïåðåíàïðÿæåíèé â òåëåôîííîé ëèíèè.

Ïðèìå÷àíèå.

Ýòî ñîåäèíåíèå íå ÿâëÿåòñÿ îáÿçàòåëüíûì äëÿ ðàáîòû ÈÁÏ.

b

Èíòåðôåéñíûé ðàçúåì RS-232

Ðàçúåì RS-232 ïîçâîëÿåò ñîåäèíèòü ÈÁÏ ñ ïîðòîì RS-232 Âàøåãî êîìïüþòå-
ðà èíòåðôåéñíûì êàáåëåì (èç êîìïëåêòà ïîñòàâêè). 

c

Âûõîäíàÿ ðîçåòêà

d

Êàáåëü äëÿ ïîäêëþ÷åíèÿ ê ïèòàþùåé ñåòè.

e

Äåðæàòåëü ïðåäîõðàíèòåëÿ. 

Ñîäåðæèò ïëàâêèé ïðåäîõðàíèòåëü, çàùèùàþùèé îò ïåðåãðóçêè ïî òîêó 
îò ïèòàþùåé ñåòè.

5

Ðóñ  

SVEN Power Pro+ 500/700

TEL/FAX

RS232

Summary of Contents for Pro+ 500

Page 1: ...PRO 500 700...

Page 2: ...SVEN Sven Ltd 2008 1 0 1 V 1 0 1 http www sven ru 2...

Page 3: ...1 4 2 4 3 4 4 Pro 500 700 4 5 5 6 5 6 1 Pro 500 700 5 6 2 Pro 500 700 5 7 6 7 1 6 7 2 6 7 3 6 7 4 6 7 5 6 7 6 7 7 7 7 7 8 7 8 8 9 8 10 9 3 SVEN Power Pro 500 700...

Page 4: ...1 Pro 500 700 2 3 1 1 2 RS 232 1 3 RJ 11 1 4 1 5 1 6 1 UPSilon 2000 Vista http www sven ru 4 PRO 500 700 120 AVR RS 232 DC 4...

Page 5: ...5 1 2 2 3 10 15 30 6 6 6 1 Pro 500 700 a b c d 6 2 Pro 500 700 a RJ 11 RJ 45 b RS 232 RS 232 RS 232 c d e 5 SVEN Power Pro 500 700 TEL FAX RS232...

Page 6: ...7 7 1 RS 232 7 2 a a 20 1 7 3 a 7 4 8 7 5 0 7 0 8 0 7 0 8 0 8 0 7 0 8 0 9 1 0 6 TEL FAX RS232...

Page 7: ...7 6 7 7 RJ 11 45 10 Base T IN OUT 7 8 4 7 SVEN Power Pro 500 700...

Page 8: ...8 9 8 1 2 3 1 2 3 1 2 3 1 2 3 1 2 1 8 2 3 5...

Page 9: ...0 VA 500 300 700 420 RISC 320 RS 232 DB 9 Windows 98 M NT 2000 XP Windows server 2003 Vista 45 1 IEC 320 EURO 0 40 C 0 90 UL cUL FCC CE TUV 165 275 50 190 245 120 130 198 242 1 5 120 130 2 3 6 12 2 8...

Page 10: ...USER S MANUAL 10 Uninterruptible Power System Please read this operation manual before using the unit and retain this operation manual in safe place for future reference...

Page 11: ...NT See the INSTALLATION SAFETY INSTRUCTIONS section in page 12 Technical support http www sven ru TABLE OF CONTENTS 1 Introduction 12 2 Safety Instructions 12 3 Package includes 12 4 The main features...

Page 12: ...UPS to Laser printer If you store the UPS or UPS does not operate for a long period recharge the battery every month by starting the UPS for 8 hours Replace the battery with the same number and type o...

Page 13: ...e b Push the Main Switch on the front panel to start the UPS Line LED Green are lit The start up procedure is completed and the loads are supplied by the UPS c To cold start the UPS press the Main Swi...

Page 14: ...rating Re connect the power cord properly Inverter LED flashes every 5 second but no output Battery voltage is too low Recharge the UPS for 8 hours Alarm buzzer beeps continuously when Utility is norm...

Page 15: ...ystem Windows 98 M NT 2000 XP Windows server 2003 Vista Indicators LEDs indicating on line on battery battery charge Alarm signals Audible signals 45 dB at 1 meter Input socket IEC 320 male socket Out...

Page 16: ......

Reviews: