5. INSTALLATION

1. Connect loading to output AVR NEO R.
2. Connect the AVR to a power line 220 V.
3. Switch on the AVR.
The indicator in the switch will be lit.
The indicator «Stabilization» will quickly be lit.
During self-testing indicators «Overload» and «Line» will be shone.
4. After 10-15 second self-testing, indicator «Overload» will go out and indicator «Line» will be lit and a voltage will 
be connected to target sockets. If indicator «Overload» after testing will not go out to maintain the stabilizer it is 
forbidden.
5. At job of the AVR boost or buck of an entrance voltage indicator «Stabilization» will be shone.
6. In case of an overload or short circuit the AVR will disconnect of a voltage. After elimination of the reason of an 
overload the stabilizer is necessary for switching on again.
7. At a voltage on an input from above 280 volt or below 150 Vac the AVR will be disconnected. Thus indicator «Overload» 
will be shone.

6. TROUBLESHOOTING

Situation

Check Items

Solution

The AVR does not work.

1. Is the power switch on?
2. Is the voltage in the entrance 
socket?
3. Too powerful loading is connected.

1. Press Main Switch on.
2. Be convinced available an 
entrance voltage.
3. Disconnect a part of loading.

The indicator «overload» does not 
die away and there is no target 
voltage.

1. Failure of the scheme of testing.
2. The AVR is faulty.
3. An entrance voltage too high.

Switch-off and anew switch on 
the AVR.
If the problem is not eliminated 
it is necessary to address in the 
service center.

The AVR often clicks, thus indicator 
«Stabilizer» lights up.

The entrance voltage is very instability.

It is normal. The AVR adjusts a 
target voltage.

The AVR has disconnected loading. 
The indicator «Overload» is shone.

An entrance voltage too high.

When the input voltage becomes 
normal the AVR will work.

7. SPECIFICATIONS

Specification/model

NEO R 1500 

NEO R 2000

Maximum load

1500 VА/750 W

2000 VА/1000 W

Input Voltage Range

150–280 V

Output Voltage Range

198—242 V (220 V ± 10%)

Protection

Over current above 7 A, short circuit, overload, against a lightning

Surge energy rating

700 J

Indicators

LEDs indicating Output off, Normal, AVR

Input 

EURO plug

Output 

4 pc. EURO 1 pc. IEC 320

Operating environment

0–40 °C, 10–90 % Rh, non condensing

Agency Approval

CE, RusTest

Frequency

50/60 hz

Dimension, mm

168 х 180 х 180

Weight, kg

5

7

Notes:

1). The specifications listed above are f or reference only.
2). The technical specifications of this device are subject to changes without prior notice.

Durability — 5 years.