5. INSTALLATION
1. Connect loading to output AVR NEO R.
2. Connect the AVR to a power line 220 V.
3. Switch on the AVR.
The indicator in the switch will be lit.
The indicator «Stabilization» will quickly be lit.
During self-testing indicators «Overload» and «Line» will be shone.
4. After 10-15 second self-testing, indicator «Overload» will go out and indicator «Line» will be lit and a voltage will
be connected to target sockets. If indicator «Overload» after testing will not go out to maintain the stabilizer it is
forbidden.
5. At job of the AVR boost or buck of an entrance voltage indicator «Stabilization» will be shone.
6. In case of an overload or short circuit the AVR will disconnect of a voltage. After elimination of the reason of an
overload the stabilizer is necessary for switching on again.
7. At a voltage on an input from above 280 volt or below 150 Vac the AVR will be disconnected. Thus indicator «Overload»
will be shone.
6. TROUBLESHOOTING
Situation
Check Items
Solution
The AVR does not work.
1. Is the power switch on?
2. Is the voltage in the entrance
socket?
3. Too powerful loading is connected.
1. Press Main Switch on.
2. Be convinced available an
entrance voltage.
3. Disconnect a part of loading.
The indicator «overload» does not
die away and there is no target
voltage.
1. Failure of the scheme of testing.
2. The AVR is faulty.
3. An entrance voltage too high.
Switch-off and anew switch on
the AVR.
If the problem is not eliminated
it is necessary to address in the
service center.
The AVR often clicks, thus indicator
«Stabilizer» lights up.
The entrance voltage is very instability.
It is normal. The AVR adjusts a
target voltage.
The AVR has disconnected loading.
The indicator «Overload» is shone.
An entrance voltage too high.
When the input voltage becomes
normal the AVR will work.
7. SPECIFICATIONS
Specification/model
NEO R 1500
NEO R 2000
Maximum load
1500 VА/750 W
2000 VА/1000 W
Input Voltage Range
150–280 V
Output Voltage Range
198—242 V (220 V ± 10%)
Protection
Over current above 7 A, short circuit, overload, against a lightning
Surge energy rating
700 J
Indicators
LEDs indicating Output off, Normal, AVR
Input
EURO plug
Output
4 pc. EURO 1 pc. IEC 320
Operating environment
0–40 °C, 10–90 % Rh, non condensing
Agency Approval
CE, RusTest
Frequency
50/60 hz
Dimension, mm
168 х 180 х 180
Weight, kg
5
7
Notes:
1). The specifications listed above are f or reference only.
2). The technical specifications of this device are subject to changes without prior notice.
Durability — 5 years.