First start of the oven.
Before the oven is first used it must be burned out so that
residual protective oil in the oven chamber disappears.
During this procedure there will be a certain amount of
smoke from the oven, but this is quite normal. Make sure
that the ventilation system in the premise is in operation,
and can get rid of the smoke.
All oven sections can be burned out at the same time.
• Close all the oven doors, open all the dampers, and set
the thermostats to approx. 120°C.
• Turn all the heat controls to Max. position and start
the oven with the main switch.
• When the oven has reached 120°C allow to stand
for about 30 minutes. Afterwards wipe off the inside
of the door glass with a dry cloth or paper.
Make sure you don’t burn yourself.
In small premises with poor ventilation it is possible that smoke
detectors are activated during the burn-out.
Use maximum ventilation by opening doors and windows.
• Turn the thermostat to approx. 200°C. Let the oven
stand for about 15 minutes when this temperature has
been reached.
• Finally, set the thermostat to 240-250°C and leave the
oven to stand for about 2 hours. The oven will now be
ready to use.
• When the oven has been switched off and has
cooled, wipe the inside of the door glass with a
moist cloth. The coating on the glass which
developed during the burn-out will otherwise stick
tight and will be very difficult to remove.
Check that the overheating protection has not triggered. If necessary,
reset according to section "Distribution box" point 1.