The SV 307 is programmed to automatically establish a remote connection with 
the SvanNET server. It can take up to 5 minutes to connect. The most important 
parameter for the connection is the Access Point Name (APN). The default setting 
for the APN is “internet”. It is possible that your specific local internet provider 
is using a different APN in which case the APN must be entered manually in the 
SvanNET application.

Access Point Name 

SvanNET Application

SvanNET Application is a 

simple software 

user interface used for the configura-

tion of the SV 307 to connect with the SvanNET service. To obtain the application 
visit www.svantek.com support page. Simply install the application on your PC, 
connect the SV 307 by the SC 316  USB cable and click “Connect to SvanNET". 

Station Configuration

Successful connection to the SvanNET server is indicated by the cloud icon. Once 
the SV 307 is connected to the basic SvanNET service it is possible to access and 
adjust its settings manually as required. Simply click the Configuration button in 
the SvanNET APP.

Summary of Contents for SV 307

Page 1: ...is capable of logging sum mary results SR and spectral data with interval steps down to 1 second Also time history results TH down to 100 milliseconds Summary results SR include LEQ PEAK MAX MIN with...

Page 2: ...d under the bottom cover of the SV 307 The bottom cover operates as a gasket therefore it is neces sary to carefully unscrew the 4 screws to remove it It is strongly recommended to configure the remot...

Page 3: ...n Access Point Name SvanNET Application SvanNET Application is a simple software user interface used for the configura tion of the SV 307 to connect with the SvanNET service To obtain the application...

Page 4: ...alarm email The configuration of Status alarms ins available in the Status tab in SvanNET Projects SvanNET Projects is an optional payable extension to the basic service offering fully automated mana...

Page 5: ...SC is located in the top of the tube direct ly above the microphone of the SV 307 System Check The ASC is based on a small speaker and the three MEMS microphones in the SV 307 Activation of the ASC en...

Page 6: ...ure continuous operation of SV 307 Use of External Battery Optionally the SB 275 external battery 33 Ah can be used to extend the autono my of SV 307 The SB 275 is simply connected to DC IN socket in...

Page 7: ...service office at the following number or contact via the SVANTEK s website Service Office 48 22 51 88 320 or 48 22 51 88 322 Office hours are 9 00 a m to 5 00 p m Central European Time E mail at offi...

Reviews: