SV 103 User Guide

SV

 

103 Technical Specification

The policy of our company is to continually innovate and develop our products.
Therefore, we reserve the right to change the specifications without prior notice.

Application

 

     

Hand-arm

Standards

 

     

ISO 8041:2005, ISO 5349-1:2001; ISO 5349-2:2001;

Meter Mode

       

ahw (RMS), ahv (VECTOR), Max, Peak, Peak-Peak 

 

 

       

A(8) Daily Exposure, ELV Time (TIME LEFT TO LIMIT), 

 

 

       

EAV Time (TIME LEFT TO ACTION)

Filters

 

     

Wh (ISO 5349) and corresponding Band Limiting filter

RMS & RMQ Detectors

 

Digital true RMS detector with Peak

 

detection, resolution 0.1 dB 

Measurement Range

    

0.2 ms

-2

 RMS ÷ 2000 ms

-2

 PEAK

Frequency Range

      

1 Hz ÷ 2000 Hz

Data Logger

 

     

Time-history data including meter mode results and spectra

Time-Domain Recording

 

Simultaneous 3-channel time-domain signal recording (option)  

Analyser

 

     

1/1 octave real-time analysis (option) 

 

 

       

1/3 octave real-time analysis (option)

Accelerometer

       

Detachable SV 107 tri-axial accelerometer with hand straps in accordance to ISO 5349

Display

 

     

OLED 128 x 32 pixels

Memory

  

8 GB

Interfaces

  

USB 2.0 client, Bluetooth

Keyboard

  

4 push buttons

Power Supply
 

 

 

Ni-MH rechargeable cells 

 

operation time > 24 hours

1

 

 

 

USB interface

    

500 mA HUB

Environmental Conditions
  

 

Temperature

  

from -10 

o

C to 50 

o

C

  

 

Humidity

  

up to 90 % RH, non-condensed

Dimensions

  

88 x 49.5 x 19.2 mm (instrument without accelerometer, cable and mounting stripe) 

 

Weight

  

150-160 grams with SV 107 accelerometer and one of  

 

 

 

 

 

 

 

 

 

vibration contact adapters

1dependent  on instrument operation configuration

Summary of Contents for SV 103

Page 1: ...SV103 Hand Arm Vibration Dosimeter User Guide ...

Page 2: ...107 moulded hand held adaptor with the tri axial MEMS accelerometer and contact force sensors The MEMS technology means the SV 107 is extremely robust shock resistant uses very low power and is free of the DC shift effect that adversely affects systems based on piezoelectric accelerometers ISO 5349 2 and EU Directive 2002 44 EC List of Contents Page 3 CONTENTS OF THE SV 103 BOX Page 4 CONFIGURATIO...

Page 3: ...es sending the instrument to SVANTEK authorised laboratory SV_CV_HA_T Accredited calibration for vibration meter ISO IEC 17025 calibration certificate List of contents included in the SV 103 box Please check the list against the contents If any of the listed items are missing please contact your local Svantek distributor or send an e mail to office svantek com within 3 days of receiving the parcel...

Page 4: ...3 settings using panels on the right hand side 8 Disconnect the USB cable Instrument is ready to measure SV 103 User Guide 4 2 Connect the USB cable to PC Make sure the Supervisor software and USB drivers are previously installed on the PC 6 Save settings file under new name 7 Upload the file to the Instrument Files using left arrow and select Apply 3 Open the Supervisor software and go to the Ins...

Page 5: ...calibrator 5 Start the calibrator using level of 10 m s2 at 80 Hz and wait until all LEDs are green 6 Press Enter on SV 103 to start the check procedure 7 Repeat the procedure for all 3 axes SV 103 User Guide 5 4 Enable Calibration menu in SV 103 by holding Right Arrow button Select the System check and axis SV110 calibrator and SA105A adapter are not the part of the SV103 kit They need to be orde...

Page 6: ...ry to use a screw for measurements Set up of SV 103 5 To start the measurement manually pres 2 arrows simultaneously SV 103 User Guide 6 4 Place the SV 107 on the palm of the hand as shown below Secure the cable on a wrist with a wrist band 2 Put the mounting adapter on arm and place the SV 103 in it ...

Page 7: ...V 103 User Guide 7 2 Select files you wish to download and click the Download button located in the bottom section 3 Once the file is downloaded it will be automatically shown in the Data Browser Right click on file and start New session or simply double click on file 5 The detailed information on the operations within the Session panels is described in the SV 103 User Manual and Supervisor Softwa...

Page 8: ...fice at the following number or contact via the SVANTEK s website Service Office 48 22 51 88 320 or 48 22 51 88 322 Office hours are 9 00 a m to 5 00 p m Central European Time E mail at office svantek com Internet at www svantek com Address SVANTEK Sp z o o Strzygłowska 81 04 872 Warszawa Poland SV 103 User Guide 8 Support and service ...

Page 9: ...1 dB Measurement Range 0 2 ms 2 RMS 2000 ms 2 PEAK Frequency Range 1 Hz 2000 Hz Data Logger Time history data including meter mode results and spectra Time Domain Recording Simultaneous 3 channel time domain signal recording option Analyser 1 1 octave real time analysis option 1 3 octave real time analysis option Accelerometer Detachable SV 107 tri axial accelerometer with hand straps in accordanc...

Reviews: