18
SETTING OF TILT UPPER LIMIT POSITION
<DF50AV/60A/60AV>
If the outboard motor contacts the motor well of
the boat during full tilt up operation, the upper
limit setting should be reset.
Perform this set-up after the current position
setting has been canceled, as explained in the
following procedure.
CANCELING THE TILT UPPER POSITION
LIMIT SETTING
1. Turn the ignition key to the “ON” position.
2. Pull out the emergency stop switch lock
plate.
3. Make sure that remote control handle is in
“NEUTRAL”.
4. Using the throttle only function of the remote
control box, move the warm-up lever upward
until the caution buzzer sounds one time.
“NEUTRAL”
5. Press the “UP” side of the PTT switch for
three seconds and the buzzer will sound
twice briefly indicating the setting has been
canceled.
6. Return the throttle to the fully closed posi-
tion.
SETTING THE TILT UPPER POSITION
LIMIT
7. Press the “UP” side of the PTT switch so
that the optimum full tilt up position for the
boat can be obtained.
8. Using the throttle only function of the
remote control box, move the warm-up lever
upward until the caution buzzer sounds one
time.
9. Press the “UP” side of PTT switch three
times within three seconds. The buzzer will
sound one time briefly indicating the setting
has been accepted.
10. Return the throttle to the fully closed posi-
tion and install the lock plate on the emer-
gency switch. Operate the full tilt up and full
down operations several times by pressing
the PTT switch and check that the setting of
both the trim lower limit and tilt upper limit
are properly set.
UP
PTT switch