4.8.  Pulsed mode 

The Pulsed mode is activated if JP1 is open and JP2 is shorted. The power must be put off / on in 
order for the pulsed mode to be activated. 

 

4.9.  Pulsed mode normal operation 

In this mode, for each active high or active low pulse on the start input, the hopper ejects a coin. 
When the hopper is started in the pulsed mode, the software inside the microcontroller of the hopper 
board will check the level of the coin-sensor first, which can be a normally open (NO) or normally 
closed (NC) type. The software needs this information in order to determine if a coin has left the 
hopper during payout. Then the motor is started forward, and coins will be ejected. After a coin has 
fully left the hopper, the software transmits an active low pulse of T_exit ms on the Coin Exit signal of 
the interface connector. See figure below. 

 

T_pulse 

 

Start 

 

 

 

 

Ready (pin 5) 

 

Hopper running and not empty 

 

 

 

 

 

 

 

 

 

Coin-Sensor (NC) 

coin enters exit port 

 

coin leaves exit port 

hopper stops 

 

 

 

 

 

Coin Exit (pin 6) 

 

                                    Start payout 

Opto Level read                                                       T_exit      Coin has left 

 

   

 

 

 

 

 

 

 

 the hopper 

 
 

Figure 6: Pulse mode timing

 

 

 

 

4.10. 

Pulsed mode anti-jam operation 

 

Refer to section 3.2.2 for a description of the anti-jam operation. 

Summary of Contents for 10-18 Series

Page 1: ...Intelligent Cube Hopper MKII Rev 2 0 Page 1 CUBE HOPPER MKII Instruction Service Manual Intelligent Cube Hopper Model 10 18XX XX Version 2 0 Apr 2013 A new design to solve most of your payout problems...

Page 2: ...us mode 9 4 3 Continuous mode normal operation 9 4 4 Continuous mode anti jam operation 10 4 5 Logic mode 11 4 6 Logic mode normal operation 11 4 7 Logic mode anti jam operation 12 4 8 Pulsed mode 13...

Page 3: ...10 0240 5 Use coin insert plate B2 Part no 10 0238 2 Coin bridge no mark Part no 10 0239 Model no 10 18XX 80 Diameter 30 10 to 31 00mm Thickness 1 50 to 2 09mm Disc is marked 8 Part no 10 0240 8 Use c...

Page 4: ...rt no 9 15 40 17 55 10 0238 9 11 18 00 18 99 10 0238 11 A 19 00 22 09 10 0238 B1 22 10 23 89 10 0238 1 B2 23 90 25 59 10 0238 2 C1 25 60 27 89 10 0238 3 C2 27 90 30 09 10 0238 4 5 30 10 31 00 10 0238...

Page 5: ...y as a coin counter Before starting a payout there should already be coins present in the coin cup These coins should be at rest before payout occurs The motor should only be active while a payout is...

Page 6: ...Gnd Low Level Low Level Start Input Mode Input Busy ready Output Coin Exit Output VIN Signal Gnd 0V JP3 JP2 Processor JP1 LEVEL TRANS Figure 1 Hopper Control Board The RS232 connector can be used to p...

Page 7: ...o the microcontroller via an opto coupler The signal common pin 8 is usually connected to the signal ground of the machine controlling the hopper The start input must be set to a voltage between 5 24...

Page 8: ...0ms 3 10 Power supply requirements 12VDC and 24VDC nominal 10 maximum ripple voltage 2 4V absolute maximum voltage 26 4VDC minimal voltage when using 24VDC connection 18VDC minimal voltage when using...

Page 9: ...ps as soon as the power is gone In this mode the Coin Exit signal output on pin 6 of the interface connector follows any level changes of the coin sensor of the hopper The Coin Exit signal will always...

Page 10: ...iod the hopper is started again If the hopper still blocks the motor will be reversed again for T_jamrev ms and then started again This procedure is repeated until the hopper starts ejecting coins aga...

Page 11: ...f a coin has left the hopper during payout Then the motor is started forward and coins will be ejected After a coin has fully left the hopper the software transmits an active low pulse of T_exit ms on...

Page 12: ...e hopper still blocks the motor will be reversed for T_jamrev ms and started again This procedure is repeated until the hopper starts ejecting coins again If the jam is not cleared the motor will stop...

Page 13: ...mally open NO or normally closed NC type The software needs this information in order to determine if a coin has left the hopper during payout Then the motor is started forward and coins will be eject...

Page 14: ...down the engraved slide on the motor housing and turn the motor housing in an anti clockwise direction to take it off Now take a new motor and refit into the motor holder The gearbox can also be remov...

Page 15: ...t or disrupt the optic signal resulting in unreliable coin counting 7 Troubleshooting 7 1 Coins fail to unjam a Are you using the correct coin insert plate see Reference Chart b Are you using the righ...

Page 16: ...opper spillage cover Part No 10 0005 Designed to prevent coin spillage TECHNICAL SPECIFICATIONS Nominal Operating Voltage 12VDC 10 or 24VDC 25 10 Minimal Operating Voltage 10 8VDC by 12V or 18V DC by...

Page 17: ...o International shall not be held liable for any loss or damage whatsoever arising from the use of any information or particulars in or any omission from this manual or any incorrect use of the produc...

Reviews: