background image

en

SUUNTO COMBOS AND MECHANICAL 
INSTRUMENTS

INSTRUCTION MANUAL

Combo Consoles I Console Compasses CB-71/STD and CB-71/DS
Depth Gauge SM-16 I Pressure Gauge SM-36

Summary of Contents for CB-71/DS

Page 1: ...en SUUNTO COMBOS AND MECHANICAL INSTRUMENTS INSTRUCTION MANUAL Combo Consoles I Console Compasses CB 71 STD and CB 71 DS Depth Gauge SM 16 I Pressure Gauge SM 36...

Page 2: ...gauges dive computers and compasses fit together like building blocks The combos consist of four main modules the pressure gauge module the instrument module and two different compass modules The pres...

Page 3: ...front cover with SM 36 pressure gauge in place see section CB ONE Module assembly 2 CB IN LINE module front cover 3 CB end piece or CB 71 STD compass optional 4 CB IN LINE module back cover with instr...

Page 4: ...sure gauge fits properly on the CB ONE module If the Suunto Quick Release is used the hose cover is not to be used See section CB ONE module assembly using the SUUNTO Quick Release After attaching the...

Page 5: ...pressure gauge which is then fitted onto the CB ONE front cover according to the picture below CB IN LINE Module Assembly The CB IN LINE module fits the Suunto Vyper and Zoop dive computers or the SM...

Page 6: ...the compass towards the destination and by reading the compass bearing from the side window This bearing can be memorized by turning the direction ring to that bearing Setting a given bearing or direc...

Page 7: ...one line up a new one farther away so that you again have three points determining your course This way you can counteract the effects of side current Compass Balancing The horizontal and vertical co...

Page 8: ...at the left side of gauge Tampering with the port can cause damage to internal components Do not pressure test gauge in air Always immerse the gauge in water while pressure testing it Pressure gauge...

Page 9: ...g other than water Use of cleaning agents or compressed air can cause permanent damage The introduction of any probe into the water entry port of the depth gauge or the pressure relief valve opening o...

Page 10: ...cifications The Suunto depth gauge SM 16 complies with the prEN 13319 standard The tolerances for depth gauges are At 3m 0 8 0 4 m At 6m 0 8 0 4 m At 9m 0 8 m At 15m 1 1 2 m At 30m 1 1 2 m At 45m 1 1...

Page 11: ...caused by misuse contrary to intended or recommended use 2 user manuals or any third party items 3 defects or alleged defects caused by the use with any product accessory software and or service not...

Page 12: ...damages including but not limited to loss of anticipated benefits loss of data loss of use cost of capital cost of any substitute equipment or facilities claims of third parties damage to property re...

Page 13: ...HELP DESK GLOBAL 358 2 284 1160 USA toll free 1 800 543 9124 CANADA toll free 1 800 267 7506 www suunto com Suunto Oy 11 2005 09 2006 11 2011 All rights reserved Suunto is a registered trademark of Su...

Reviews: