APPLICATION NOTE
TELULAR SX5 SERIES PHONE CELL & XPERT2/9210B SPEECH MODEM (OR 8210-3014 MODEM)
16
8. 8210 TO FWT VOICE OPERATION
The 8210-3014 is normally used to announcing voice sounds of the sensor digital recorded values
over the standard phone line in this case as the FWT connected unit. Connect the 8210 to the FWT
using the Sutron supplied RJ11 adapter 6411-1159-1 and FWT supplied RJ11 cable as shown in Figure
17.
Figure 17. 8210 RJ11 adapter to FWT RJ11 jacks
Be sure the RED wire connects to the RING terminal block connection on the side of the 8210 terminal
strip. The 8210 operations manual page 5-2 covers some detail on setup. Also necessary is entries
into the 8210 MODEM Setup Menu for 10 digit numbers and voice messages to be spoken by the
8210. See pages 4-40 to 4-53 for information.
Be sure to set the 8210 answer mode to voice. The other modes such as data, Voice and Data and
Data and Voice are not supported by the combination of speech board and Telular modem.
Once the FWT is set with the 10 digit number the default settings are voice.
9. 8210 TO FWT DATA OPERATION
The 8210 logger along with XPert modem (8080-0005-1) may be used as standard HAYES data modem
with the FWT by placing the FWT in the data mode. This configuration utilizes the 8210 external TERM
port. A typical setup is shown in Figure 18. A standard serial cable together with a NULL MODEM
adapter plug is required for connecting to the speech modem as shown in Figure 18.
9.1 8210 Configuration
Set the 8210 as follows:
Scroll using the DOWN arrow so the EEROM SETUP is visible.