Bringing the Benefits of Real-Time Data Collection to the World
Sutron Corporation, Tel: 703-406-2800 http://www.sutron.com
Table of Contents
1.
Introduction .......................................................................................................................... 1
Features .................................................................................................................................... 1
2. Quick Start ............................................................................................................................ 2
3.
SDI-12 Commands (Overview) ........................................................................................... 4
Setting the Address ................................................................................................................... 4
Verifying the Address and Operation ....................................................................................... 5
Making a Measurement ............................................................................................................ 6
Selecting a measurement command class ................................................................... 6
Always supported ........................................................................................ 6
Multiple long measurement time sensors ..................................................... 6
Improved data integrity checking ................................................................ 6
Example: (M command) ............................................................................................ 6
C, MC and CC commands.......................................................................................... 7
Other Measurements .................................................................................................. 7
Factory Programmed Default Measurements ........................................................................... 7
M, C, MC, CC ............................................................................................. 7
M1, C1, MC1, CC1 ..................................................................................... 8
M2, C2, MC2, CC2 ..................................................................................... 8
M3, C3, MC3, CC3 ..................................................................................... 8
M4, C4, MC4, CC4 ..................................................................................... 8
M5, C5, MC5, CC5 ..................................................................................... 8
M6, C6, MC6, CC6 ..................................................................................... 8
M7, C7, MC7, CC7 ..................................................................................... 8
M8, C8, MC8, CC8 ..................................................................................... 8
M9, C9, MC9, CC9 ..................................................................................... 8
4. Measurements ...................................................................................................................... 9
Setting a Measurement (Quick Set-up With Default Parameters) ............................................ 9
Voltage Measurement (Single-ended) ........................................................................ 9
Voltage Measurement (Differential) .......................................................................... 9
Ratiometric Measurement .......................................................................................... 9
Tipping-Bucket Measurement .................................................................................... 10
Counts Measurement .................................................................................................. 10
Frequency Measurement ............................................................................................ 10
Period Measurement .................................................................................................. 10
Quadrature Shaft Encoder Measurement ................................................................... 11
Notes on Handar 436 Quadrature Ecoder (any switch closure output encoders) ....... 11
State of Port ............................................................................................................... 12
Setting a Measurement (Specific Set-up With User-Defined Parameters) ............................... 13
Voltage Measurement ................................................................................................ 13
SDI-12 set-up command .............................................................................. 13
Examples ..................................................................................................... 14
Verification and Reading current Set-up...................................................... 14
Ratiometric Measurement .......................................................................................... 15
SDI-12 set-up command .............................................................................. 15
Examples ..................................................................................................... 16
Verification and Reading current Set-up...................................................... 16
Tipping-Bucket Measurement .................................................................................... 17
SDI-12 set-up command ............................................................................. 17